Chapter 5 – Wiring
5-2
3)
If more than one motor is to be driven by a single inverter, thermal relays have to be provided for each
motor.
Thermal relay
L100IP
4)
The leads from the power supply must be connected to the mains circuit terminals as follows:
Connect single phase power supply (50/60Hz) to terminals L1, N.
Connect three phase power supply (50/60Hz) to terminals L1, L2, L3.
Wiring the control terminals
The following figure shows the location of the control terminals. The exact use of each of the control
terminals is described later in this chapter.
The figure below contains an example for control terminal wiring: