15
1. Send data (Setting command. Note: 1 to 7 and SUM need to be transformed into ASCII code)
1
2
3
4
5
6
7
Item
STX
STATUS ID NO.
AREA
ADDRESS
RELATIVE
NO.
DATA
ETX SUM
OFF
02
01
FF
01
04
00
00
00
03
28
FIXED
02
01
FF
01
04
01
00
00
03
27
1TRIG
02
01
FF
01
04
02
00
00
03
26
MODE
VD CONT
02
01
FF
01
04
04
00
00
03
24
POSITIVE
02
01
FF
01
0F
00
00
00
03
16
POLARITY
NEGATIVE
02
01
FF
01
0F
01
00
00
03
15
CL-CC1
02
01
FF
01
05
00
00
00
03
26
TRIGGER
SOURCE
12pin
02
01
FF
01
05
01
00
00
03
25
OFF
02
01
FF
01
06
00
00
00
03
26
FLASH OUT
02
01
FF
01
06
01
00
00
03
25
OUTPUT SIGNAL
VD
02
01
FF
01
06
02
00
00
03
24
OFF
02
01
FF
01
08
00
00
00
03
24
1/30
02
01
FF
01
08
01
00
00
03
23
1/60
02
01
FF
01
08
02
00
00
03
22
1/100
02
01
FF
01
08
03
00
00
03
21
1/250
02
01
FF
01
08
04
00
00
03
20
1/1000
02
01
FF
01
08
05
00
00
03
1F
1/2000
02
01
FF
01
08
06
00
00
03
1E
1/10000
02
01
FF
01
08
07
00
00
03
1D
1/50000
02
01
FF
01
08
08
00
00
03
1C
PRESET
VARIABLE (*2)
02
01
FF
01
08
FF
00
00
03
F8
MIN (1/100000(s)) 02
01
FF
01
11
00 (*3) 00 (*3)
00
03
2A
SHUTTER
SPEED
(*1)
VARIABLE VALUE
(2Byte) (*2)
MAX (10(s))
02
01
FF
01
11
06 (*3) 00 (*3)
00
03
1E
8bit
02
01
FF
01
14
00
00
00
03
27
10bit
02
01
FF
01
14
01
00
00
03
26
DATA BIT
12bit
02
01
FF
01
14
02
00
00
03
25
VD
02
01
FF
01
15
00
00
00
03
26
VD/FVAL
FVAL
02
01
FF
01
15
01
00
00
03
25
HD
02
01
FF
01
16
00
00
00
03
25
HD/LVAL
LVAL
02
01
FF
01
16
01
00
00
03
24
MIN (-6dB:0)
02
01
FF
01
0C
00
00
00
03
19
(0dB:168)
02
01
FF
01
0C
00
A8
00
03
00
GAIN (2Byte)(*4)
MAX(18dB:671)
02
01
FF
01
0C
02
9F
00
03
F8
MIN (0)
02
01
FF
01
17
00 (*5)
00
00
03
24
BLACK LEVEL
MAX (63)
02
01
FF
01
17
3F (*5)
00
00
03
0B
OFF
02
01
FF
01
13
00
00
00
03
28
VERTICAL 2 PIXEL
ADDITION
ON
02
01
FF
01
13
01
00
00
03
27
OFF
02
01
FF
01
1E
00
00
00
03
16
MODE
ON (*6)
02
01
FF
01
1E
01
00
00
03
15
MIN (1)
02
01
FF
01
1F
00
01
00
03
14
START
(2BYTE) (*6)
MAX (1040)
02
01
FF
01
1F
04 (*7) 10 (*7)
00
03
10
MIN (1)
02
01
FF
01
20
00
01
00
03
29
PARTIAL
SCAN
WIDTH
(2BYTE) (*6)
MAX (1040)
02
01
FF
01
20
04 (*7) 10 (*7)
00
03
25
OFF
02
01
FF
01
50
00
00
00
03
27
H-LAMP
02
01
FF
01
50
01
00
00
03
26
V-LAMP
02
01
FF
01
50
02
00
00
03
25
TEST PATTERN
HV-LAMP
02
01
FF
01
50
03
00
00
03
24
FACTORY SETTING
SET
02
01
FF
01
45
01
00
00
03
22
(*1) SHUTTER SPEED settings are effective only in the condition TRIGGER MODE is OFF or FIXED SHUTTER.
(*2) VARIABLE VALUE can be set only when VARIABLE is selected.
(*3) VARIABLE VALUE: selectable in the range from 0000 to 0600
16
(See page 5 to 6 about setting shutter speed).
(*4) GAIN: selectable in the range from 0000
16
to 029F
16
. Factory setting is 00A8
16
.
(*5) BLACK LEVEL: selectable in the range from 00
16
to 3F
16
.
(*6) PARTIAL SCAN START/WIDTH can be set only when PARTIAL SCAN MODE is ON.
(*7) PARTIAL SCAN START/WIDTH: selectable in the range from 0001
16
to 0410
16
and the sum total of START and WIDTH is 0411
16
or less.
Command list
Summary of Contents for KP-F145WCL
Page 6: ...E ...