30
d) (A.E) GATE line7-8
(CSR: F200 0088 h)
-Manual adjustment-
Setting value 820xx0yy h
xx: LINE 7 ON/OFF bit map data
yy: LINE 8 ON/OFF bit map data
(A.E) GATE line1-2 to line7-8 setting examples
Screen detect areas
Setting values corresponding to detect areas
Detect area (ON): 1 Non-detect area (OFF): 0
7
6
5
4
3
2 1 0
GATE
line1-2
xx
values 0
0
0
0
0
0 0 0
GATE
line1-2
yy
values 0
0
0
0
0
0 0 0
GATE line3-4 xx values
0
0
0
0
0
0
0
0
GATE line3-4 yy values
0
0
1
1
1
1
0
0
GATE line5-6 xx values
0
1
1
1
1
1
0
0
GATE line5-6 yy values
0
1
1
1
1
1
0
0
GATE line7-8 xx values
0
1
1
1
1
1
0
0
GATE line7-8 yy values
0
1
1
1
1
1
0
0
Values for setting the above map detection area
(A.E) GATE line1-2: 82 00 00 00 h
(A.E) GATE line
3-4
: 82 00 00 3C h
(A.E) GATE line
5-6
: 82 07 C0 7C h
(A.E) GATE line
7-8
: 82 07 C0 7C h