18
-Manual adjustment-
Setting value 8x0y0000 h
x
:
2- LOW ACTIVE, 3- HIGH ACTIVE
y
:
0- MDOE0, 1- MODE
1
Trigger mode polarity is switched at external signal values x and y.
See trigger operation details and timing chart (page 39).
(10)
INITIALIZE
(CSR:
F0F0
0000
h)
Return equipment to status at time of release from factory.
-Initialization-
Setting value 80000000 h
(11) MEMORY SAVE (EXECUTE)
(CSR: F0F0 0618 h)
Make back up of presently effective memory channels.
-BACK UP execute-
Setting value 80000000 h
(12) MEMORY SAVE (Ch SET)
(CSR: F0F0 0620 h)
Select channel carried out memory backup.
-channel set-
Setting value x0000000 h
x: 1- ch1, 2- ch2, 3- ch3, 4- ch4
(13) CURRENT MEMORY
(CSR: F0F0 0624 h)
Loading memory channel designating data
-LOAD BACK UP-
Setting value
x0000000 h
x: 0- FACTORY SETUP, 1- ch1, 2- ch2, 3- ch3, 4- ch4
Summary of Contents for HV-F22F
Page 60: ...46 Dimensions ...