15
-Manual adjustment-
Setting value 82000xxx h
xxx: (HV-F22) 7C5h to B6Ch / (HV-F31) 789h to B27h
Electronic shutter can be set in the range of 4 to 1/100,000 second.
Shutter speed setting value can be derived as follows.
OFF_SPEED
= 15 (HV-F22), 30 (HV-F31).
•
Cause of shutter speed
≦
(1 / OFF_SPEED)
a) Setting value obtained from fluorescent time.
nnnh = 800h + log
0.99
(
OFF_SPEED
×”Shutter Speed”)
b) Fluorescent time obtained from setting value.
Shutter Speed[sec] =
OFF_SPEED
× 0.99
(nnn
―
800h)
Ex. 1
Fluorescent time with HV-F31 = setting value nnn to obtain 1/100 second.
800h+ log
0.99
(30×(1/100))
= 800h+ log(30×(1/100)) / log0.99
= 878h
Ex. 2
Setting value nnn that produces 1/100 second fluorescent time with HV-F31F.
(1/30) × 0.99
(878h
-
800h)
= 1/100(sec)
•
Cause of shutter speed > (1 / OFF_SPEED)
a) Setting value obtained from fluorescent time.
nnnh = 801h - (
OFF_SPEED
×”Shutter Speed” )
b) Fluorescent time obtained from setting value.
Summary of Contents for HV-F22F