Rollkolbenverdichter 

Rotary Compressors

Spezifikation 

Installation Manual

WHP09100VUKPA8LT6

RIES GmbH, Rudolf-Diesel-Str. 10, D 64569 Nauheim, GERMANY 

Phone: +49 6152 9741 0, Fax: +49 6152 9741 21, Email: 

[email protected]

, Website: www.ries-gmbh.de 

R 410A, R 452B - R 454C- R 454B

22,6 cm3/rev

900 - 7200 min-1

DC/ BLDC

Summary of Contents for Highly WHP09100VUKPA8LT6

Page 1: ...ezifikation Installation Manual WHP09100VUKPA8LT6 RIES GmbH Rudolf Diesel Str 10 D 64569 Nauheim GERMANY Phone 49 6152 9741 0 Fax 49 6152 9741 21 Email info ries gmbh de Website www ries gmbh de R 410A R 452B R 454C R 454B 22 6 cm3 rev 900 7200 min 1 DC BLDC ...

Page 2: ...sor specifications 3 Motor parameters 4 General characteristics 5 Parts and drawings list Second the heat pump water heater dedicated compressor use benchmark 5 15 Third Acceptance basis and rules 16 1 Acceptance basis 2 Acceptance rule Fourth the drawings 17 29 Fifths Revision experience 30 ...

Page 3: ... 4 Application Heat pump water heater 2 5 Performance 性 能 参 数 Refrigerant R410A R452B R454B R454C Item Rated Condition Rated Condition Rated Condition Rated Condition Rotational speed 3600 min 1 3600 min 1 3600 min 1 3600 min 1 Nominal Heating Capacity 9105W 8830W 8785W 6245W Motor input 2115W 2025W 2010W 1340W Current 7 6A 7 5A 7 4A 5 2A COP see 4 30 4 36 4 37 4 66 Measuring condition Evaporating...

Page 4: ...ment 22 6ml rev 2 8 Allowable frequency range 900 7200 min 1 2 9 Oil HAF68 630 20ml 2 10 Allowable amount of refrigerant c h a r g e Below 2100g 2 11 Compressor cooling Forced air 2 12 Hermetic Terminal Conventional type 2 13 Space volume of inner case 1200cm 3 2 14 Compressor weight 10 2kg incl Oil 2 15 Motor Type Insulation class Direct current brushless motor E class 3 THE PARAMETER OF MOTOR It...

Page 5: ...isture 120mg MAX 4 4 Residual impurities 60mg MAX 3 4 Inductance Ld mH Sheet 2 3 5 Inductance Lq mH Sheet 2 3 6 Stator coil resistance 20 Ω 0 93 line to line 3 7 Voltage Constant Vrms krpm 42 8 line to line 3 7 Torque Constant N m Arms 0 60 Torque Current 3 9 Inertia Kg m2 0 000388 3 10 Flux Φa Wb 0 1110 φ Per Phase Peak 3 2 0 2 f E π 3 11 Magnet Material NdFeB Current RMS 1 0 2 0 3 0 4 0 5 0 6 0 ...

Page 6: ...ioned sketch Mounting Parts Rubber grommet Bolt Nut 3 4CYC01088 M10 M10 Electrical Parts Terminal cover Gasket Nut Rubber washer Thermostat Sleeve 1 1 1 1 1 1 4CYC01114 4CYC01113 3CYC00004 4CYC00174 4CYC01045 4CYC01042 4CYC01268 1 2 3 Lead routing Pressure guarantee Chart Oil level datum Notes for rotational speed change Out of supply for reference ...

Page 7: ...erated in the range of rated voltage 10 under standard condition and overload condition of rated frequency applied voltage to inverter It must be satisfied with item 5 6 7 4 Operating temperatures and pressures The operating temperatures and pressures of a compressor should be within the range shown in the table 2 and graph 1 5 Oil Back and height of the oil level Oil should be returned continuous...

Page 8: ...sing temperature 65 2 97 MAX condensing temperature 70 Suction Pressure MPa 0 27 1 66 0 26 1 59 0 26 1 57 0 20 1 19 Evaporation Temperature 30 25 It can also be 0 101 0 272 MPa when in transition but should not be used when it is less than 0 101MPa Compressor case bottom temp 99 or below and 6 degrees higher than condensing temperature Motor winding temp Rated voltage 105 MAX R Voltage 10 120 MAX ...

Page 9: ...Current limitation Current peak among motor terminals include instantaneous current peak should be below demagnetizing current in order to prevent magnet in motor from demagnetization 7 Pressure difference between suction and discharge In all allowable rotational speed range the difference of pressure should be more than 0 39MPa 4kgf cm 2 But if there is no problem of noise when assembled in air c...

Page 10: ...suring the temperature of hermetic terminals lead wire should be resist to the temperature and be clamped so as not in touch with the surface of compressor and pipe 11 Start stop frequency The frequency should be less than 6 times per hour Operating time from start to stop should be more than 3 minutes Stopping time should be more than 3minutes 12 Rate of rotational speed change The rate of compre...

Page 11: ...oil acids washing fluid used at machining heat exchanger and tubes 15 Compressor vacuum operation Compressor should never be operated while under vacuum Otherwise internal arcing can cause damaging parts 16 The compressor should be operated for more than 20 seconds within 15 minutes after charging refrigerant into the system so proper lubrication results 17 Liquid refrigerant return limitations 1 ...

Page 12: ... such as automobiles trains ships etc 20 Installation The rotational axis of compressor should be kept vertical during operation But in actual application the axis incline must be within 5 at all directions during operation 21 Pipe vibration The displacement of the pipes which connect from the compressor to other parts of the refrigerate or systems should be less than 0 8mm 1 32 when the compresso...

Page 13: ...ld not apply partial force on projection parts such as pipe hermetic terminals foot during carrying and processing 2 The compressor should not be operated to form a vacuum and to absorb air The compressor only can run in one direction which according to lead routing wiring diagram Never reversion otherwise thecompressor will be in trouble 3 The compressor should not be left opened in the atmospher...

Page 14: ...be charged from the end of condenser of refrigerating systems Never Charge refrigerant to the compressor directly The refrigerant should always be charged in liquid state When the refrigerant is charged in gas state The percent component will possibly be changed 10 Temperatures within systems during stable compressor operation should not be less than 35 to prevent wax precipitation from the oil 11...

Page 15: ...sor to reach the temperature higher than 10 with heater if the ambient temperature is below 10 19 Set a thermistor on the case cover of compressor to prevent from accident of leakage of refrigerant The thermistor can stop the operation of compressor when compressor in abnormal temperature The lead wires of thermostat is enveloped with tube as same as that of the terminals to avoid directcontact wi...

Page 16: ...r 23 Be careful of avoiding oxide scale while soldering during assembly of refrigerating system for example flow or fulfill dry nitrogen 24 The quantity and kind of contamination the process materials in the cycle should be grasped and managed Carry on reliability test that input contamination a lot than anticipated contamination quantity 25 To avoid water and impurity into he refrigeration system...

Page 17: ...use or and breaker should be equipped in the main circuit 28 The thickness of the refrigerating system using tube the tube thickness as followed external diameter mm 6 35 9 52 12 7 15 88 19 05 22 2 25 4 31 75 38 1 44 45 Thickness mm 0 8 0 8 0 8 1 1 1 1 1 1 1 4 1 5 ...

Page 18: ...lar electrical appliances General requirements and GB 4706 17 Safety of household and similar electrical appliances Particular requirements for motor compressor 2 Rule for Checking upon Delivery If come across any quality problem please notify the company in written form within 30 days after the arrival of the cargo the company shall exchange exactly the number of the products otherwise they shall...

Page 19: ...17 30 ...

Page 20: ...18 30 ...

Page 21: ... 19 30 ...

Page 22: ...20 30 ...

Page 23: ...21 30 ...

Page 24: ...22 30 ...

Page 25: ...23 30 ...

Page 26: ...24 30 ...

Page 27: ...25 30 ...

Page 28: ...26 30 ...

Page 29: ...Rotational speed rpm Pd limit MPa R410A R452B R454B R454C a 900 3 50 3 22 2 25 b 2400 4 00 3 72 2 75 c 5400 4 28 4 00 2 97 d 7200 3 50 3 22 2 25 900 1800 min 1 27 30 ...

Page 30: ...Chart 2 DC INVERTER COMPRESSOR OIL LEVEL DATUM 28 30 ...

Page 31: ...29 30 ...

Page 32: ...Specification Revision Record No Date Page in Spec Revision Reason Conclusion Date A B C D E F G H J K L M N P Q R S U V 30 30 ...