--- 13 ---
8-5. Wiring Diagram
(1) Models G 18SR/G 23SR
(2) Models G 18SRU/G 23SRU
8-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance, and conduct the dielectric strength
test.
Insulation resistance: After switch is turned on, more than 10 M
Ω
by 500 V DC megohm meter between live
parts and accessible metal parts.
Dielectric strength: After switch is turned on, there must be no trouble when the voltage indicated below is
provided between live parts and accessible metal parts.
Less than 150 V of rated voltage: 3,000 V x 3 sec.
More than 150 V of rated voltage: 4,400 V x 3 sec.
8-7. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) max.
110
8.0
220
3.6
230
3.9
240
3.8
Wiring dia.
Wiring dia.
Summary of Contents for G 18SR
Page 34: ......