-4-
On completion of disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation resistance: 7 M
Ω
or more with a 500 VDC megohm tester
Dielectric strength test: 4,000 VAC/minute, with no abnormalities ---------- 230 V
2,500 VAC/minute, with no abnormalities ---------- 110 V
After no-load operation for 30 minutes, the no-load current values should be as follows.
Voltage
110 V
230 V
Current max.
3.5 A
2.0 A
No-load current value
Fig. 5
Wiring diagram
Stator
[9]
Pushing Button Switch
[32]
Black
Brown
Blue
Stator
[9]
Black
Black
Red
1
C1
White
Black
2
C2
Varistor (A) Ass’y
[43]
Controller
Gray
Insulation test