53 | 108
E-Compact MP-BB3 Series
> Main Menu > System Alarms/Log > Clear Alarm Log:
Resets the main alarm list.
Select “On” to reset the Alarms Log list.
Control Module Main Alarm List
DRAWER ALARM
ALARM DESCRIPTION
THRESHOLD
SYSTEM
ACTION
Driver Low RF Input Level
Driver RF Input is lower than threshold.
-8 dBm
Notification
Driver High Temperature
Driver Temperature is greater than
threshold.
75 ºC (167 °F)
Notification
Critical High Forward Power
HPA Forward Power is greater than
threshold.
330W
@PA702MP ATSC3.0
380W
@PA702MP ATSC1.0
650W
@PA704MP ATSC3.0
750W
@PA704MP ATSC1.0
Shutdown
Critical High Reflected Power
HPA Reflected Power is greater than
threshold.
45W
@PA702MP ATSC3.0
50W
@PA702MP ATSC1.0
90W
@PA704MP ATSC3.0
100W
@PA704MP ATSC1.0
Shutdown
High Input Air Temperature
Ambient air temperature used in the reflow
of the equipment is greater than threshold.
40 °C (104 ºF).
Notification
Critical High Input Air
Temperature
Ambient air temperature used in the reflow
of the equipment is greater than threshold.
48 °C (118.4 °F)
Notification
Fan warning
Fan rotation reaches ±1000RPM in relation
to software programmed value.
1000 RPM
Notification
Fan Failure
Fan rotation reaches ±2000RPM in relation
to software programmed value.
2000 RPM
Notification
MAIN ALARM
ALARM DESCRIPTION
High Power Amplifier Communication
Control Module cannot communicate with Power Amplifiers
High Power Amplifier Active Alarm
Current alarm on one or more Power Amplifiers
Exciter Fail
Control Module cannot communicate with Exciter
ALC Max
Automatic Level Control set to maximum and not able to
drive the output power required
uC Communication Fail
Web Server cannot communicate with microcontroller
Interlock Failure
Interlock protection disabled
RF Mute
RF Output muted by itself or by an external command
Over Power
Output Power exceeded allowed limit
Reflected Power
Reflected Power exceeded the minimum allowed!
Output Power Zero
Output power not detected by Directional Coupler
Reduction Power by Reflected
Power reduced to comply with reflected power limit
Reduction Power by High Power Amplifier
Power reduced to comply with maximum power provided by
each power amplifier
Reduction Power by HPA High
Temperature
When the HPA reaches 87 °C (188.6 °F), it reduces the
power by 3dB. Returns the rated power when the
temperature is restored to 80 °C (176 °F).
Summary of Contents for EC702MP-BB3
Page 68: ...68 108 E Compact MP BB3 Series VGS Carrier Software Version 1 75 1 70 1 71 1 78 ...
Page 84: ...84 108 E Compact MP BB3 Series B220 BIPHASIC 220VAC 2 PHASE 110VAC GND ...
Page 85: ...85 108 E Compact MP BB3 Series M220 SINGLEPHASE 220VAC 1 PHASE NEUTRAL GND ...
Page 106: ...106 108 E Compact MP BB3 Series Section 8 Attachments ...
Page 108: ...108 108 E Compact MP BB3 Series ...