Section 4 - Initial Activation (ATSC Transmitters)
Manual Rev. 0.0 - April 2016
4-3
>
>
If the input signal (TS) is present, just the led PAST ALARM shall remain lit.
Resetting the status of older alarms (PAST ALARM)
Select
System Alarms/Log
in the Main Menu [0000] and press ENTER.
Select
Clear Alarm Log
[3000]. Press ENTER.
Deleted alarms, LED PASTALARM deleted.
Verification of the communication Status between Power drawer and the Exciter
In the
Main Menu
screen, select
Measurements
and press ENTER.
Select
Communication Satus
and press ENTER.
In the [2500] screen will be shown the communication Status RS485 with the power drawer.
NOTE: Only the SYNC LOSS TS 1 and SYNC LOSS TS 2 Fail alarms are acceptable.
>
>
>
>