WARNING:
Death, personal injury and/or property damage may occur unless instructions are
followed carefully.
•
Disconnect battery cables when charging battery.
•
Use battery of specified capacity listed in the owner’s manual.
•
Turn the starter switch to the “STOP” position when mounting or dismounting battery. Connect
positive (+) terminal first when mounting battery, and disconnect negative (–) terminal first when
dismounting.
Red cable: to the positive (+) terminal
Black cable: to the negative (–) terminal
CHECK COMPONENT PARTS
Check following items before starting engine:
1. Fuel leakage from fuel hose, etc.
2. Bolts and nuts for looseness.
3. Components for damage or breakage.
4. Generator not resting on or against any adjacent wiring.
OPERATION
STARTING GENERATOR
WARNING:
Before starting the generator, be sure that you read and understand all the safety
and operating instructions in this manual.
1. Make sure that the AC switch (no-fuse breaker) is “O” (OFF).
2. Turn the fuel cock to the vertical (open) position.
3. Pull the choke knob to the fully closed position.
NOTE:
Be sure to pull the choke even if the engine is warm.
Fig. 15
Fig. 16
Fig. 17
“I” (ON)
“O” (OFF)
Close
Open
Close
Close