Do not use motor hooks.
fig.3.3 VB-110-E2
Eyebolt
Less than 60
°
Do not use motor hooks.
Fig.3.2 VB-040 to 080-E2
Eyebolt
2. Installation Direction
•
In order to keep the shaft of the Vortex Blower level, mount the Vortex Blower
horizontally (see Horizontal Installation below).
•
Wall or upright installation is possible for models VB-019(S)-E-U or smaller. In these
instances, verify that blower unit faces downward (see Vertical Installation I below).
Do not perform vertical installation VB-030E-U or larger.
•
Do not perform vertical installation as shown in Vertical Installation II.
Upper Part
Upper Part
Lower Part
Lower Part
Motor
Unit
Blower
Unit
Motor
Unit
Blower
Unit
Blower Unit
Horizontal Installation Vertical Installation I Vertical Installation II
(Do not perform this installation
on VB-030E-U and larger)
3. Installation Location
•
Installation of the Vortex Blower should be indoors.
- 10 -