63 | 106
E-Compact Medium Power
Sparkovers types:
PHASE
2807586
150VAC SURGE
PROTECTION VARISTOR
Ground
Ground
B240
PHASE
PHASE
PHASE
PHASE
2798844
275VAC SURGE
PROTECTION VARISTOR
Ground
Ground
M208
NEUTRAL
NEUTRAL
PHASE
2817990
260VAC SURGE
PROTECTION SPARKLER
Never open the device: there is a risk of electric shock. If necessary, contact Hitachi
Service.
Before Connecting the Machine to the AC Mains, one must ensure that the grid
Voltage meets the equipment’s settings.
Never expose the equipment to rain, moisture or direct sunlight, in order to avoiding risk of
fire or electric shock.
2798844 – 275VAC SURGE PROTECTION VARISTOR
2817990 – 260VAC SURGE PROTECTION SPARKLER
2807586 – 150VAC SURGE PROTECTION VARISTOR
About AC MAINS TYPE, see Section 8 –
Attachments, USA AC Mains Types for E-
Compact Series.