6.1.4. Control System Operation
6.1.4.1. Navigation
The Control Module CM8001 has a system of configuration, measurements, alarms and remote
management (TELESUPERVISION), that controls all the modules of the transmitter.
The configuration of the transmitter might be done either by its front panel, of the transmitter or the web
interface using a browser of your choice or SNMP.
When the device is turned on, or when it enters in stand-by mode (idle for 5 minutes), the display
switches between the following status screens:
01
Current date
06
Transmission System:
02
Current time
ATSC 1.0
03
Operation UHF channel number
ATSC 3.0
04
Real Output Power Value (Watts)
07
Power Equipment Model
05
Equipment Model:
08
Double Exciter Status
EC702MP EC704MP
CM8001 Main “Ctr A”:
Active / Standby
CM8001 Backup “Ctr B”:
Active / Standby
01
02
05
06
07
08
03
04