6 - 9
6) Choose the radio button of corresponding model name in
MODEL SELECT screen.
7) Click the ENTER button in MODEL SELECT screen,
and then proceed with the SETUP MENU screen.
Refer to next item for subsequent operations.
If there is an error in model selection, the FILE HANDLE
ERROR dialog will appear. Click the OK button, and then
choose the correct model.
Note:
If the FILE HANDLE ERROR dialog appears when the
correct model has been chosen, obtain (download) the
newest adjustment software, and then start over again.
If the FILE HANDLE ERROR dialog still appears with
the newest adjustment software, check with the factory.
MODEL SELECT screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
MODEL SELECT
× × × ×
× × × ×
ENTER
EXIT
CONNECTION
× × × ×
× × × ×
6
7
SETUP MENU screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
Matrix
EXECUTE
RETURN
SETUP MENU
White Balance Abs
White Balance
FILE HANDLE ERROR dialog
ERROR
!
File hundle error. [SYMBOL FILE]
OK
Adjustment > Creating Reference Data
(2) Termination
1) Click the RETURN button on MENU screen of software to return to the MODEL SELECT screen.
2) Click the EXIT button on the MODEL SELECT screen.
Information:
If the PC does not accept any operation during work, or the reference data creating software does
not work, perform the following procedure:
1) Set the power switch of reference data creating device to “OFF”.
2) Turn off the DC power supply of DSP-R jig.
3) Simultaneously press the Ctrl, Alt and Delete keys on PC keyboard to restart the PC.
4) After the PC restarts, set the power switch of reference data creating device to “Movie” and
turn on the DC power supply of DSP-R jig again.
5) Restart the reference data creating software.