![Hitachi DH 52ME Service Manual Download Page 15](http://html.mh-extra.com/html/hitachi/dh-52me/dh-52me_service-manual_145569015.webp)
-14-
• Mounting handles (A) and (B)
(7) Mounting handles (A) and (B)
(a) Insert the Handle Shaft
<86>
into Handle (A)
<70>
and fix it with the Screw D4 x 25
<79>
.
(b) Insert the Cord
<85>
and Cord Armor
<82>
and then fix the Cord Clip
<83>
with the Screw D4 x 16
<84>
. Bring the flat side of the Cord Clip
<83>
in contact with the Cord
<85>
when mounting.
(c) Insert the hinge shaft of Handle (A)
<70>
into the hinge hole of the Back Cover
<87>
and fix Handle
(A)
<70>
to the Transatory Unit
<72>
with Distance Piece (B)
<69>
and the Bolt M5 x 12
<68>
.
(d) Fit the Filter PCB Ass’y
<71>
, On Lock PCB (A) Ass’y
<92>
, On Lock Spring
<91>
, On Lock Button
<90>
, Pillar Terminal (A)
<81>
, the connectors to connect On Lock PCB (A) Ass’y
<92>
and
Controller Ass’y
<63>
, Switch
<77>
, and Trigger
<76>
into the positions shown in the figure.
NOTE: Do not insert the Filter PCB Ass’y <71>, On Lock PCB (A) Ass’y <92>, and On Lock
Button <90> in the wrong direction.
(e) Put the internal wires in Handle (A)
<70>
and mount Handle (B)
<79>
without getting the internal
wires caught.
The blue-colored capacitor of the Filter PCB
Ass’y
<71>
must be on the back cover side.
<76>
<77>
<81>
<90>
<91>
<72>
<92>
Connector to connect On
Lock PCB (A) Ass’y
<92>
and Controller Ass’y
<63>
<70>
Connector to connect the
Filter PCB Ass’y
<71>
and
Controller Ass’y
<63>
Install Handle (B)
<79>
with the internal wires
and connectors pushed in not to protrude from
the rib of Handle (A)
<70>
.