Deskstar T7K500 Hard Disk Drive Specification
195
Sector Count Current
The number of continuous sectors to be transferred low order,
bits (7:0)
Sector Count Previous
The number of continuous sectors to be transferred high
order, bits (15:8). If zero is specified in the Sector Count
register, then 65,536 sectors will be transferred.
Sector Number Current
LBA (7:0).
Sector Number Previous
LBA (31:24).
Cylinder Low Current
LBA (15:8).
Cylinder Low Previous
LBA (39:32).
Cylinder High Current
LBA (23:16).
Cylinder High Previous
LBA (47:40).
Input Parameters From The
Device
Sector Number (HOB=0)
LBA (7:0) of the address of the first unrecoverable error.
Sector Number (HOB=1)
LBA (31:24) of the address of the first unrecoverable error.
Cylinder Low (HOB=0)
LBA (15:8) of the address of the first unrecoverable error.
Cylinder Low (HOB=1)
LBA (39:32) of the address of the first unrecoverable error.
Cylinder High (HOB=0)
LBA (23:16) of the address of the first unrecoverable error.
Cylinder High (HOB=1)
LBA (47:40) of the address of the first unrecoverable error.
CCTO (Error, bit 0)
CCTO bit shall be set to one if a Command Completion Time
Limit Out error has occurred.
SE (Status, bit 5)
SE (Stream Error) shall be set to one if an error has
occurred during the execution of the command and the RC bit
is set to one. In this case the LBA returned in the Sector
Number registers shall be the address of the first sector in
error, and the Sector Count registers shall contain the num-
ber of consecutive sectors that may contain errors. If the
RC bit is set to one when the command is issued and a UNC,
IDNF, ABRT, or CCTO error occurs, the SE bit shall be set to
one, the ERR bit shall be cleared to zero, and the bits that
would normally be set in the Error register shall be set in
the error log.
DWE (Status, bit 4)
DWE (Deferred Write Error) shall be set to one if an error
was detected in a deferred write to the media for a previous
Write Stream DMA or Write Stream PIO command. This error is
from a previously issued command. If DWE is set to one, the
location of the deferred error is only reported in the Write
Stream error log.
Feature Current
Summary of Contents for Deskstar T7K500
Page 2: ......
Page 18: ...Deskstar T7K500 Hard Disk Drive Specification 4 ...
Page 20: ...Deskstar T7K500 Hard Disk Drive Specification 6 ...
Page 21: ...Deskstar T7K500 Hard Disk Drive specification 7 Part 1 Functional specification ...
Page 22: ...Deskstar T7K500 Hard Disk Drive Specification 8 ...
Page 24: ...Deskstar T7K500 Hard Disk Drive Specification 10 ...
Page 34: ...Deskstar T7K500 Hard Disk Drive Specification 20 ...
Page 55: ...Deskstar T7K500 Hard Disk Drive Specification 41 Part 2 Interface specification ...
Page 56: ...Deskstar T7K500 Hard Disk Drive Specification 42 ...
Page 80: ...Deskstar T7K500 Hard Disk Drive Specification 66 ...
Page 82: ...Deskstar T7K500 Hard Disk Drive Specification 68 ...
Page 90: ...Deskstar T7K500 Hard Disk Drive Specification 76 ...
Page 142: ...Deskstar T7K500 Hard Disk Drive Specification 128 ...