35
CP-X205W (C14-20N) / CP-X305W (C14-25N)
By the control panel
By the remote control transmitter
1. Display the Advanced menu by
the “MENU” button.(If EASY
MENU appears, choose “Go to
Advanced menu” to display
ADVANCED MENU.)
2. Select the “OPTION” on the
menu.
3. Continue press the button [ ]
fi
rst, then press the button [ ]
together with “INPUT”, and hold
for 3 seconds.
1. Display the menu by the
“MENU” button. (If EASY
MENU appears, choose “Go to
Advanced menu” to display
ADVANCED MENU.)
2. Select the “OPTION” on the menu.
3. Press the “MAGNIFY OFF”
button.
Next hold the “MAGNIFY OFF”
button for 3 seconds.
To display the OSD for “HIDDEN SERVICE MENU” set up.
HIDDEN SERVICE
AIR-SENSOR EXECUTE
LAMP ALARM
NONE
PJLink
TURN OFF
STARTUP TYPE
1
PANEL TIME
1234h
NETWORK RESET
SOFT RESET
6-13 HIDDEN SERVICE MENU
6-14 RUN TIME window
AIR - SENSOR
Execute this item to adjust the air sensor.
PJLink
Select the PJLink. Turn off
↔
Turn on
LAMP ALARM
Select the lamp alarm level. 3 Level
↔
1 Level
↔
None
“3 Level” shows three kinds of lamp-messages according to the LAMP TIME count.
“1 Level” shows one kind of lamp-message according to the LAMP TIME count.
“None” shows no lamp-messages. It is the factory default setting.
STARTUP TYPE
Select the startup screen type. 1 : shows Hitachi Logo
2 : No Hitachi Logo
PANEL TIME
Use time of LCD panel. Reset the PANEL TIME whenever you changed the LCD/LENS prism assembly.
NETWORK RESET
If this is executed, all of the network setting are initialized.
SOFT RESET
If this is executed, all of the user data is initialized.Never use it when not required.
Set operating time display method (accumulated lamp time display method)
1. Select “OPTION” from the Advanced menu, then place the cursor on the “LAMP TIME”.
2. Press the [ ], [ENTER] or [RESET] button.
3. Press the [Reset] button once, then press [KEYSTONE] button of the remote control for 3 seconds or
more to display the screen shown below. (The menu will close after 10 seconds if there are no further
operations.)
4. Use [ ] or [ ] to select the usage status number. (The usage status is as shown below.)
Usage status number
0 ..... Total usage status
1 ..... Current usage status
2 ..... Usage status before first reset
3 ..... Usage status before second reset
||
9 ..... Usage status before eighth reset
RUN TIME
LAMP
Lamp time
1234h
h
h
h
NORMAL
Lamp time(Normal)
1000
WHISPER
Lamp time(Whisper)
234
AC
2000
AC energizing time
On
Number of times on
1
Off
Number of times off
No.0
Usage status number(See below)
0