26
CP-X205W (C14-20N) / CP-X305W (C14-25N)
6-5 Air filter
WARNING
• Before caring, make sure the power switch is off and the power cable is not plugged in, then allow the
projector to cool suf
fi
ciently. The care in a high temperature state of the projector could cause an electric
shock, a burn and/or malfunction to the projector.
• Use only the air
fi
lter of the speci
fi
ed type. Do not use the projector with the air
fi
lter and the
fi
lter cover
removed. It could result in a
fi
re and/or malfunction to the projector.
• The air
fi
lter should be cleaned periodically. If the air
fi
lter becomes clogged by dust or the like, internal
temperatures rise and could cause a
fi
re, a burn and/or malfunction to the projector.
NOTE
• Please replace the air
fi
lter when it is damaged or too soiled, and also when you replace the lamp.
• Please reset the
fi
lter time only when you have cleaned or replaced the air
fi
lter, for a suitable indication
about the air
fi
lter.
• The projector may display the message such as “CHECK THE AIR FLOW” or turn itself off, to prevent the
internal heat level rising.
If the air
fi
lter becomes clogged by dust or the like, internal temperatures rise and could cause a
fi
re, a burn
and/or malfunction to the projector. When the indicators or a message prompts to clean the air
fi
lter, clean
the air
fi
lter as soon as possible.
Please check and clean the air
fi
lter periodically, even if there is no message.Please replace the air
fi
lter
when it is damaged or too soiled.
And also when you replace the lamp, please replace the air filter. An air filter of specified type will come
together with a replacement lamp for this projector.
1. Turn the projector off, and unplug the power cord. Allow the lamp to cool
for at least 45 minutes.
2. When the projector is suspended from the ceiling, apply the vacuum cleaner
to and around the
fi
lter cover
fi
rst, to prevent penetration of dust or the like.
3. Pull the
fi
lter cover knobs while lifting it. The
fi
lter unit which consists of the
fi
lter' cover, air
fi
lter and
fi
lter frame will come off.
4. Use a vacuum cleaner for the
fi
lter vent of the projector and the
fi
lter frame
side of the
fi
lter unit.
If the air
fi
lter is damaged or too soiled, replace it according to the following
procedure number 5 to 7.
Otherwise, please jump to the procedure number 8.
5. Pull the
fi
lter frame' knob up while holding the
fi
lter cover. The
fi
lter frame will
come off and the air
fi
lter will appear.
6. Replace the air
fi
lter with new one.
7. Put the
fi
lter frame back.
8. Put the
fi
lter unit back into the projector.
9. Turn the projector on and reset the
fi
lter time using the FILTER TIME item in
the EASY MENU.
(1) Press the MENU button to display a menu.
(2) Point at the “FILTER TIME” using the
▼
/
▲
button, then press the
►
button. A dialog will appear.
(3) Press the
▲
button to select “RESET” on the dialog. It performs resetting the
fi
lter time.
Filter cover
Filter cover knobs
Filter unit
Filter frame
Air
fi
lter
Filter cover