CP-S210 (C10S)
Power can not be turned on
Are
voltage input
at pins ,
, , of
E800 on the PWB assembly
Main at standby
mode?
: +12V
: +17V
: +6.6V
: +4.1V
Power unit (circuit)
Fuse
on the Filter unit
Filter unit
NO
YES
Disconnect
TSW form Power unit
(circuit). And check
TSW short or
open?
PWB assembly Main
Short
TSW
Open
What is the state of
TEMP indicator D302?
Not light
DC FAN
Blinks
Jump to * on the page 13
What is the state of
LAMP indicator D303?
Not light
Blinks
1
1
3
5
7
3 5 7
H (More than 12.6V)
Measure
voltage at the
of
E803 on the PWB
assembly Main.
L (OV)
PWB assembly Limit SW
PWB assembly Main
Is the LAMP DOOR
set?
OK
Set the LAMP DOOR
NG
2
15
Summary of Contents for CP-S210 series
Page 7: ...Remote control transmitter 7 ...
Page 31: ...31 7 Wiring diagram ...
Page 32: ...32 ...
Page 33: ...33 ...
Page 40: ...40 10 RS 232C communication ...
Page 41: ...41 ...
Page 42: ...42 ...
Page 43: ...43 日本語 中文 ...
Page 44: ...44 ...
Page 45: ...45 ...
Page 46: ...46 ...
Page 47: ...47 09 00 Filter missing 10 00 Inside Temp sensor out ...
Page 54: ...PWB assembly MAIN 1 C10S 54 ...
Page 55: ...PWB assembly MAIN 2 C10S 55 ...
Page 56: ...PWB assembly MAIN 3 C10S 56 ...
Page 57: ...PWB assembly MAIN 4 C10S 57 ...
Page 58: ...PWB assembly MAIN 5 C10S 58 ...
Page 59: ...PWB assembly MAIN 6 C10S 59 ...
Page 60: ...PWB assembly MAIN 7 C10S 60 ...
Page 61: ...PWB assembly MAIN 8 C10S 61 ...
Page 62: ...PWB assembly MAIN 9 C10S 62 ...
Page 63: ...PWB assembly MAIN 10 C10S 63 ...
Page 64: ...Memo Memo 64 ...