CP-S210 (C10S)
Adjustment procedure 1
(when a color differential meter is used)
1. First adjust [MID-L] tone [G:].
2. Select adjustment point [No.2][G:].
When the background is not [G] monochrome,
press the [ENTER] key on the Remote control
transmitter to change to solid [G] monochrome.
3. Measure the illumination at adjustment points No.
2, No.3, No.10 and No.11.
The values should be:
No.2 = Y2 [lx] No.10 = Y10 [lx]
No.3 = Y3 [lx] No.11 = Y11 [lx]
4. No.2 and No.3 adjustment point have the average
of Y2 and Y3.
Y2 = ( Y2 + Y3 ) / 2 ± 2 [%]
Y3 = ( Y2 + Y3 ) / 2 ± 2 [%]
5. No.10 and No.11 adjustment point have the
average of Y10 and Y11.
Y10 = ( Y10 + Y11 ) / 2 ± 2 [%]
Y11 = ( Y10 + Y11 ) / 2 ± 2 [%]
6. Then adjust [MID-L] tone [R] and [B].
When the background is [G] monochrome, press
the [ENTER] key on the Remote control
transmitter to change to solid white.
7. Measure the color coordinates of adjustment
point [No.1] and make a note of them.
Assume that they are x = x1, y = y1.
Note:
Wh e n th e C L -1 0 0 co l o r a n d co l o r
difference meter is used, the [ ](delta)
mode is convenient. When adjustment
point [No.1] color coordinate has been
selected, set the slide switch on the side to
[ ](delta) while holding down the [F] button
on the front panel. The measurement
shown after this displays the deviation from
measurement point 1.
8. Measure the color coordinates of measurement
point [No.2] and adjust [No.2][R:] and [B:] so that
the coordinates are as follows.
x = x1 ± 0.005 , y = y1 ± 0.010
9. Similarly, measure adjustment points [No.3] to
[No.17] and adjust their color coordinates starting
in order from the small number points.
This completes adjustments required for [MIN].
Note:
Since excessive correction may lead to a
correction data overview during internal
calculations, use the following values for
reference.
[No.2] to [No.5] ± 40 or less
[No.6] to [No.9] ± 50 or less
[No.10] to [No.13] ± 70 or less
[No.14] to [No.17] ± 120 or less
10. Then adjust [MIN] tone [G] so that the adjustment
data set two times as much as [MID-L] tone [G].
This completes [G] color adjustments.
11. Then adjust [MIN] tone [R] and [B].
Select [No.2] [B:] and press the [ENTER] key on
the Remote control transmitter to change to solid
white.
12. Measure the color coordinates of adjustment
point [No.1] and make a note of them.
Assume that they are x = x1, y = y1.
13. Now measure the color coordinates of
measurement point [No.2] and adjust [No.2][R:]
and [B:] so that the coordinates are as follows.
x = x1 ± 0.005 , y = y1 ± 0.010 (Target)
x = x1 ± 0.020 , y = y1 ± 0.040
14. Similarly, measure adjustment points [No.3] to
[No.17] and adjust their color coordinates starting
in order from the small number points.
This completes [MIN] tone adjustments.
15. Now make similar adjustments for [MID-H] tone.
(Adjust [MID-H] tone [G] so that the adjustment
data set half as many as [MID-L] tone [G].)
16. Now make similar adjustments for [MAX] tone.
(Adjust [MAX] tone [G] so that the adjustment
data set half as many as [MID-L] tone [G].)
11
Summary of Contents for CP-S210 series
Page 7: ...Remote control transmitter 7 ...
Page 31: ...31 7 Wiring diagram ...
Page 32: ...32 ...
Page 33: ...33 ...
Page 40: ...40 10 RS 232C communication ...
Page 41: ...41 ...
Page 42: ...42 ...
Page 43: ...43 日本語 中文 ...
Page 44: ...44 ...
Page 45: ...45 ...
Page 46: ...46 ...
Page 47: ...47 09 00 Filter missing 10 00 Inside Temp sensor out ...
Page 54: ...PWB assembly MAIN 1 C10S 54 ...
Page 55: ...PWB assembly MAIN 2 C10S 55 ...
Page 56: ...PWB assembly MAIN 3 C10S 56 ...
Page 57: ...PWB assembly MAIN 4 C10S 57 ...
Page 58: ...PWB assembly MAIN 5 C10S 58 ...
Page 59: ...PWB assembly MAIN 6 C10S 59 ...
Page 60: ...PWB assembly MAIN 7 C10S 60 ...
Page 61: ...PWB assembly MAIN 8 C10S 61 ...
Page 62: ...PWB assembly MAIN 9 C10S 62 ...
Page 63: ...PWB assembly MAIN 10 C10S 63 ...
Page 64: ...Memo Memo 64 ...