-9-
(2) The following cautions are listed on the Nameplate attached to the Type BCL 1015 Storage Battery.
[ For Europe ]
[ For the USA and Canada ]
(3) The following cautions are listed on the Nameplate attached to the Type UC 10SFL Storage Battery.
[ For the USA and Canada ]
2. Precautions on Efficient Use of The charger and battery
(1) Battery possibly not rechargeable immediately after use
If the Type BCL 1015 Battery is exposed to direct sunshine for an extended period or becomes very
hot immediately after being used in the Model CH 10DL/CG 10DL, the pilot lamp may not light up
even though the battery is connected to the charger. The Type BCL 1015 Battery is rechargeable
when its temperature is within the range specified in the table below. Customers should be advised to
place a hot battery in a shaded area with good airflow and allow for sufficient cooling before
recharging. The cooling time required before charging varies from a few minutes to about 10 minutes,
depending on the load, duration of use and ambient temperature.
<Rechargeable battery temperature range>
Battery temperature
Battery
Model UC 10SFL Charger
Type BCL 1015
0 to 50
q
C