Identifying rebuild status
After you replaced an HDD, the RAID will be rebuilt automatically. To restore
the RAID subsystem after an HDD replacement, you need to check whether
the RAID rebuild was successful by using Internal Storage Monitor.
If Internal Storage Monitor is not installed in your server blade, you must
install it from the Utility CD-ROM/DVD-ROM in advance.
The basic procedure for identifying the rebuild progress is as follows.
Figure 6-1 Basic procedure for identifying the rebuild progress
In hot-swap (Internal Storage Monitor)
Windows environment
1
.
Click internal storage monitor icon to start the application. When the
icon is not available, click Start > all programs(P) > Server
installation and monitoring tool > internal storage monitor >
internal storage monitor in Windows 2008 server.
2
.
Confirm that internal storage monitor main window is displayed.
3
.
Confirm whether the Fault LED on the replaced HDD is blinking. When the
rebuild is in progress on the HDD, the Fault LED blinks in amber.
6-2
Identifying RAID rebuild status
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...