background image

 

 

 

Facility names and functions (Rear)

 CU-HD1300F-S3

 

 

  9   

TALK ON/OFF switch 

Intercom microphone on/off switch. 

10

 

INTERCOM LEVEL control 

Adjusts intercom listening volume. 

11

 

Intercom connector (XLR,5P) 

Connection for optional MT-12MF headset. 
(refer to p30) 

12

 

HD/SD-SDI connectors (BNC) 

Output  eight  lines  of  serial  digital  HDTV/SDTV 
video signals. 

Select  the  HD-SDI  or  SD-SDI  by  the  user 
function menu. 
The character is superimposed in PIX output. 

 

 

13   High Speed OUTPUT connectors (BNC) 

Outputs  2  sets  of  three  times  high  speed 
signals as LINK A, LINK B and LINK C. 
[

1080i or 720p

 

 

 

Output Signals 

SYSTEM FORMAT 

1080i/59.94Hz 

1080i/50.00Hz 

HIGH SPEED 

OUTPUT 

1080/59.94i, 

720/59.94p 

1080/50i, 

720/50p 

HD/SD 

OUTPUT 

1080/59.94i, 

720/59.94p, 

480/59.94i 

1080/50i, 

720/50p, 

576/50i 

 

 

Summary of Contents for CA-HF1300-S3

Page 1: ...Super Slow Motion Fiber System Camera Adaptor Fiber CCU CA HF1300 S3 CU HD1300F S3 OPERATING INSTRUCTIONS Please read these operating instructions carefully for proper operation and keep them for future reference ...

Page 2: ......

Page 3: ...important for you to keep for your convenience and protection These numbers appear on the nameplate located on he bottom of the product Please record these numbers in the spaces provided below and retain this manual for future reference Model No Serial No ...

Page 4: ...e to equipment Caution notes indicate any condition or practice which if not strictly observed or remedied could result in damage or destruction of the equipment NOTE Notes indicate an area or subject of special merit emphasizing either the product s capabilities or common errors in operation or maintenance WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS COLOR CAMERA TO RAI...

Page 5: ...sive force and uneven surfaces may cause the product and cart combination to overturn 10 Ventilation Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating and these openings must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or other similar surface ...

Page 6: ...ervice personnel under the following conditions a When the power supply cord or plug is damaged b if liquid has been spilled or objects have fallen into the product c If the product has been exposed to rain or water d If the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment o...

Page 7: ...em Wagen Stand Dreifuß Träger oder Tisch verwenden der vom Hersteller empfohlen oder mit dem Erzeugnis verkauft worden ist Für jegliche Anbringung sollten die Anweisungen des Herstellers befolgt werden und das vom Hersteller empfohlene Anbringungszubehör sollte verwendet werden 9 Eine Kombination von Erzeugnis und Wagen sollte vorsichtig bewegt werden Schneller Halt übermäßige Krafteinwirkung und ...

Page 8: ...Art auf das Erzeugnis verschütten 17 Entflammbare und explosive Substanzen Vermeiden Sie Verwendung dieses Erzeugnisses an Orten mit Gasen bzw entflammbaren oder explosiven Substanzen in der direkten Umgebung 18 Starke stöße oder Vibrationen Setzen Sie das Erzeugnis beim Transport nicht starken Stößen oder Vibrationen aus 19 Wartung Versuchen Sie nicht dieses Erzeugnis Selbst zu warten da Sie sich...

Page 9: ...e den Wartungstechniker nach der Vollendung von Wartung oder Reparaturarbeiten an diesem Erzeugnis um die Durchführung von Sicherheitsprüfungen um zu bestimmen daß das Erzeugnis im angemissenen Betriebszustand ist 23 Anbringung an der Wand oder an der Decke Das Erzeugnis sollte nur entsprechend den Empfehlungen des Herstellers an einer Wand oder an der Decke angebracht werden 24 Wärme Das Erzeugni...

Page 10: ... arrêts brusques une force excessive et des surfaces irréguliéres pourraient provoquer le renversement de l ensemble appareil chariot 10 Ventilation Les fentes et les ouvertures du coffret sont prévues pour la ventilation ainsi que pour garantir un fonctionnement en toute sécurité de l appareil et le protéger de toute surchauffe et ces ouvertures ne devront donc être ni obstruées ni recouvertes Ne...

Page 11: ... le cordon d alimentation ou sa fiche sont endommagés b Si du liquide s est renversé sur l appareil ou que des objets sont tombés dedans c Si l appareil a été exposé á la pluie ou á l eau d Si l appareil ne fonctionne pas normalement lorsqu on observe les instructions d utilisation Ne régler que les commandes couvertes par le mode d emploi en effet un réglage incorrect des autres commandes pourrai...

Page 12: ... improvement Confirm the most recent specifications at time of order Hitachi Kokusai Electric certifies this product complies with the standard warranty conditions of Hitachi Kokusai Electric and that quality control is implemented to the extent required to comply with those conditions Warranty and service 1 The guarantee period is one year after the data purchase However the defects due to errone...

Page 13: ... S3 4 Facility names and functions Rear CU HD1300F S3 5 System configuration Mode selection method 7 System configuration Hybrid fiber optic cable mode 8 Function menu 11 Cable check Warning indication 21 Warning indication 22 Backup battery replacement 23 Service information 24 External View 30 Specifications 31 ...

Page 14: ......

Page 15: ... servers Flexible acceptability to versatile video formats HDTV and SDTV Digital outputs 3 times HIGH SPEED OUTPUT LINK A B C 6x BNC Link A x2 Link B x2 Link C x2 1080i 720p HD SD OUT 1 2 3 6x BNC HD SDI SD SDI selectable 1080i 720p SD SDI PIX WFM OUT 2x BNC HD SDI SD SDI selectable 1080i 720p SD SDI Digital inputs DIGITAL RET IN 1 2 3 4 RET B IN 1 2 6x BNC 3G SDI HD SDI SD SDI 1080p 1080i 720p SD...

Page 16: ...ations Impaired performance and damage can be caused Extremely hot or cold locations exceeding 0 to 40 C such as in enclosed vehicles Subject to strong vibration Humid or dusty locations Salt spray or corrosive gases Strong electromagnetic fields e g near TV or radio transmitters Where exposed to rain When connecting and disconnecting cables grasp the connector by the body not the attached cable C...

Page 17: ...for handling 1 Cable Connector Receptacle 1 FCF Fiber Cable Female 2 FCM Fiber Cable Male 3 FCFR Female Receptacle 4 FCMR Male Receptacle 2 Maintenance tool information 1 Cleaning Stick CANARE CLETOP 2 5 2 0 2 CLEANING KIT Fiber optical cable assembly manufacture CANARE has Cleaning kit for the optical fiber cable connector available Detail is in URL http www canare co jp ...

Page 18: ... in cable Note CAMERA POWER switch 2 is inoperative when OPEN SHORT LED is lighted 5 CABLE CONDITION LED HEAD The strength of the arriving light signal from Camera Head to CCU is indicated by LED CCU The strength of the arriving light signal from CCU to Camera Head is indicated by LED Optical fiber operation Indicate the receiver level approximately GREEN1 3dBm to 8dBm Normal GREEN2 8dBm to 11dBm ...

Page 19: ...C Output eight lines of serial digital HDTV SDTV video signals Select the HD SDI or SD SDI by the user function menu The character is superimposed in PIX output 13 High Speed OUTPUT connectors BNC Outputs 2 sets of three times high speed signals as LINK A LINK B and LINK C 1080i or 720p Output Signals SYSTEM FORMAT 1080i 59 94Hz 1080i 50 00Hz HIGH SPEED OUTPUT 1080 59 94i 720 59 94p 1080 50i 720 5...

Page 20: ...gnal for the prompter The signal is sent to PROMPT out connector on CA HF1300 S3 20 Fiber connector Connect Fiber cable 21 AC IN connector Input for AC power supply AC input range is 100V to 240V 47 to 63Hz with auto sensing 23 MIC OUT connector XLR 3pin Outputs MIC1 audio signals from a camera refer to p30 24 MIC REMOTE connector This connector is used to select the MIC amplifier gains refer to p...

Page 21: ... combined with camera adaptor CA HF1300 S3 Use a HFOC Hybrid Fiber Optic Cable between the camera adaptor and CCU OPT SINGLE Optical fiber operation is available combined with camera adaptor CA HF1300 S3 Use a SMF Single mode Fiber between the camera adaptor and CCU Supply external power DC12V to the camera adaptor because CCU does not send power C C U F U N C T I O N B U Z Z E R E N A B L E S D I...

Page 22: ...e CAMERA POWER button can be turned on to supply the camera power NOTE When the camera power is turned off and restarted it takes approx 10 seconds to enable the CAMERA POWER button Camera Head SK HD1300 S3 Optical Fiber Cable Camera control unit CU HD1300F S3 Camera Adaptor AC input CA HF1300 S3 Slow motion video server Third party High speed output Link A B C SU Setup control unit SU 1000 Remote...

Page 23: ...UNCTION menu Note The setting can be changed in standby mode camera power off 5 Supply DC12V power to the DC IN connector of CA HF1300 S3 6 Set the POWER switch of CA HF1300 S3 to EXT side Example screen of CU FUNCTION menu Camera head SK HD1300 S3 Single mode fiber cable Camera control unit CU HD1300F S3 Remote control unit RU 1500JY S3 Camera adaptor CA HF1300 S3 AC plug DC12V AC DC Converter AC...

Page 24: ...ical cable Viewfinder VF 402 S3 Camera control unit CU HD1300F S3 Remote control unit RU 1500JY S3 Camera adaptor CA HF1300 S3 Camera head SK HD1300 S3 SU Viewfinder VF L90HD Build up adaptor BU 1000 VF adaptor AT S900 Lens mounter LM B1000 Lens mounter LM P1000 Microphone adaptor MH 1000 Viewfinder VF L90HD HDF EL800H Setup control unit SU 1000 Tripod adaptor TA Z3 Portable lens Studio adaptor SA...

Page 25: ...ontrol unit SU 1000 to the CU UHD4000 to display the function menus on PIX video output The function menus include the CCU menu to adjust the CCU and the camera menu to adjust a camera See each Operation Instruction for RU 1500 and SU 1000 operation RU 1500JY MENU control section on LCD ...

Page 26: ... 1080i HD SD1 1 2 1080i HD SD2 1 2 1080i HD SD3 1 2 1080i WFM PIX 1080i ACPEST SD 16 9 LAN SETTING IP 192 168 1 75 CONF 192 168 1 75 SUBNET 255 255 0 0 CONF 255 255 0 0 GATEWAY 192 168 1 254 CONF 192 168 1 254 SET PUSH SETTING OK SUBNET SETTING SUBNET 255 255 0 0 SEND 255 255 0 0 EDIT OCTET1 255 OCTET2 255 OCTET3 0 OCTET4 0 SEND PUSH SEND GATEWAY SETTING GATEWAY 192 168 1 254 SEND 192 168 1 254 ED...

Page 27: ...SYS FORMAT submenu TIME DATE Moves to the TIME DATA submenu Item Setting Factory setting Description SYS FORMAT 59 94Hz 50 00Hz Sets the video frame rate Move the cursor to the system frequency you want to set and press button SET DATA Within 10 seconds after setting the video frame rate press both and buttons together to fix the SYS FORMAT setting Item Setting Factory setting Description DATE DIS...

Page 28: ...your monitor can receive the signal format 3 RETURN SELECT menu Item Setting Factory setting Description CH1 RET 1 RET 2 RET 3 RET 4 RET 1 Assigns the return video signal to CH1 selected when CA HF1300 S3 RET switch is set to 1 CH2 RET 2 Assigns the return video signal to CH2 selected when CA HF1300 S3 RET switch is set to 2 CH3 RET 3 Assigns the return video signal to CH3 selected when CA HF1300 ...

Page 29: ...onnected to CCU COMMUNICATION connector For the detail of this pin diagrams see page 31 TALLY SET CONTACT VOLTAGE CONTACT Sets the power supply method for TALLY CONTACT when not supplying external power VOLTAGE when supplying external power Item Setting Factory setting Description GL H PHASE 128 2048 to 127 2047 108 1728 Adjusts whole system phase against genlock signal HD H PHASE 128 512 to 127 5...

Page 30: ...PIX OUT For more detail of this see page 25 CAM ID OFF ON ON Displays Camera ID number on color bars CCU ID OFF ON ON Displays CCU ID number on color bars CCU IP OFF ON ON Displays CCU IP address on color bars OUTPUT ALL PIX ALL Selects output channels that display CAM ID CCU ID CCU IP on color bars ALL Displays on all output channels PIX Displays on only PIX output CAM CAB CON OFF ON OFF Displays...

Page 31: ... DEP SLP 128 to 127 128 Adjusts the slope of detail effect on dark area of image Item Setting Factory setting Description SD MASKING OFF ON OFF Enable the linear masking effect specialized for SDTV R G 128 to 127 0 Adjust liner matrix R G parameter offset R B 128 to 127 0 Adjust liner matrix R B parameter offset G B 128 to 127 0 Adjust liner matrix G B parameter offset G R 128 to 127 0 Adjust line...

Page 32: ... is updated if OCTET1 to OCTET4 setting values are changed OCTET1 0 to 255 192 The current OCTET1 setting value is displayed Press or button to select OCTET1 setting value OCTET2 0 to 255 168 The current OCTET2 setting value is displayed Press or button to select OCTET2 setting value OCTET3 0 to 255 4 The current OCTET3 setting value is displayed Press or button to select OCTET3 setting value OCTE...

Page 33: ...o LAN SETTING MENU description Item Setting Factory setting Description GATEWAY The current GATEWAY address of CCU is displayed The expression of IP address is OCTET1 OCTET2 OCTET3 OCTET4 SEND OCTET1 OCTET2 OCTET3 OCTET4 setting value is displayed The display of SEND is updated if OCTET1 to OCTET4 setting values are changed OCTET1 0 to 255 0 The current OCTET1 setting value is displayed Press or b...

Page 34: ...and F number of lens iris are displayed at the bottom of the PIX screen FILTER No Mode ND FILTER CAP 1 2 3 4 CAP CLEAR 1 4 ND 1 16 ND 1 64 ND CC Color Temperature Correction FILTER A B C D E 3200 K 4300 K 5600 K 7500 K FAW PIX OUT camera status display 4 1 64ND A 3200K F8 0 ND filter CC filter Lens F number ...

Page 35: ...OPEN OR CHECK CAMERA POWER CAMERA CABLE SINGLE LED OPEN lights Cable is not connected Camera power defaults to off and camera power switch is rendered inoperative Cable mode is Selected the SINGLE PIX OUT CCU FAN ALARM FAN warning of CCU The internal fan is stopped or the rotating speed is lowered PIX OUT CAMERA FAN ALARM FAN warning of camera head or camera adaptor The adaptor internal fan is sto...

Page 36: ... POWER SW to CCU PIX OUT SUPPLY DC12V IN CX CA HF1300 S3 needs external power Connect external power to CA HF1300 S3 PIX OUT CAM HEAD PWR OFF CCU does not supply power to CA HF1300 S3 PIX OUT CCU FAN ALARM The CCU FAN is abnormal The FAN stops or rotary speed declines by deterioration PIX OUT CX FAN ALARM The CA HF1300 S3 FAN is abnormal The FAN stops or rotary speed declines by deterioration When...

Page 37: ...battery should be replaced and the date and time should be adjusted at the TIME DATE menu WARNING Be sure to replace the battery with a type CR2032 lithium battery Using another type of battery can damage the camera and pose a fire hazard Also be sure to dispose of the depleted battery as prescribed by local ordinance e g return it to the dealer Do not dispose of the battery with combustible waste...

Page 38: ... 1 MIC GND 2 MIC H IN 3 MIC C IN Remote 1 2 4 pin female HR10A 7R 4S 73 Combined connector HR10A 7P 4P Pin Signal 1 12V output 2 DATA input 3 DATA output 4 DATA ground TALLY OUT 9pin D sub female RDED 9S LNA 4 40 55 Combined connector 9pin D sub male Application circuit example Plug CCU mainframe Internal circuit Pin Pin Signal 1 1 R TALLY 1 2 2 R TALLY 2 3 3 G TALLY 1 4 4 G TALLY 2 5 5 6 6 7 7 NC...

Page 39: ...C 2W NC 6 6 PD IN H 2W NC 5 5 ENG OUT C 2W OUT IN C 4 4 ENG OUT H 2W OUT IN H 3 3 ENG SHIELD 2 2 ENG IN C 2W NC 1 1 ENG IN H 2W NC 25 25 GND 24 24 23 23 NC 22 22 TALLY COMMON TALLY COMM 21 21 G TALLY IN G TALLY IN 20 20 R TALLY IN R TALLY IN 19 19 NC 18 18 PGM2 IN C 17 17 PGM2 IN H 16 16 PGM SHIELD 15 15 PGM1 IN C 14 14 PGM1 IN H 17 18 19 TALLY COMM Contact supply Voltage supply TALLY IN 24V TALLY...

Page 40: ...Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Pin Signal 1 5V OUT 200mA max 2 TALLY GND 3 G TALLY OUT 4 R TALLY OUT 5 MIC1 GAIN CTL2 6 MIC1 GAIN CTL1 7 MIC1 GAIN CTL0 8 MIC SEL1 9 GND 10 11 NC 12 MIC2 GAIN CTL2 13 MIC2 GAIN CTL1 14 MIC2 GAIN CTL0 15 MIC SEL2 CTL0 CTL1 CTL2 MIC AMP GAIN STANDARD TYPE S Hi Hi Hi 70dB 50dB Lo Hi Hi 60dB 40dB Hi Lo Hi 50dB 30dB Lo Lo Hi 40dB 20dB Hi Hi Lo 30dB 10dB Lo Hi Lo...

Page 41: ...l 1 1 2 2 WFM CTL0 3 3 WFM CTL1 4 4 WFM CTL2 5 5 WFM CTL3 6 6 WFM CTL4 7 7 WFM CTL5 8 8 WFM CTL6 9 9 WFM CTL7 10 10 11 11 12 12 13 13 14 14 15 15 SHIELD MODE CTL0 CTL1 CTL2 CTL3 CTL4 CTL5 CTL6 CTL7 R Lo Hi Hi Hi Hi Hi Hi Hi G Hi Lo Hi Hi Hi Hi Hi Hi B Hi Hi Lo Hi Hi Hi Hi Hi ENC Hi Hi Hi Lo Hi Hi Hi Hi SUP Hi Hi Hi Hi Lo Hi Hi Hi SEQ Hi Hi Hi Hi Hi Lo Hi Hi ...

Page 42: ...er when you make setting change Camera Head SK HD1300 S3 Camera Adaptor CA HF1300 S3 Optical Fiber Cable Camera Control Unit CU HD1300F S3 Remote Control Unit RU 1500 Headset Carbon Headset Carbon Equipment side connector specification INTERCOM 5 pin XLR female HA16PRH 5S Combined connector 5pin XLR male Headset mic Input specification Carbon type 10dBu Pin Signal 1 TALK C 2 TALK H 3 RECEIVE C 4 R...

Page 43: ...HD1300F S3 The Intercom setting for carbon type headset 1 Loosen two screws of the front panel and open a panel 2 Set up the switch in a unit according to the headset to be used 3 Close the front panel and tighten a two place screw ...

Page 44: ...30 External View CU HD1300F S3 外観図 Unit mm ...

Page 45: ...x2 Link C x2 1080i or 720p SMPTE292M HD SD OUT 1 2 3 6x BNC HD SDI SD SDI selectable Embedded 2 Chnl audio available 1080i 720p SMPTE292M SD SDI SMPTE259M C PIX WFM OUT 2x BNC HD SDI SD SDI selectable Embedded 2 Chnl audio available 1080i 720p SMPTE292M SD SDI SMPTE259M C MIC OUT1 1x XLR 3 pin 0 dBm 600Ω MIC OUT2 1x XLR 3 pin 0 dBm 600Ω INTERCOM HEAD SET 1x XLR 5 pin 0 dBu MAX 15 dB Remote1 1x 4 p...

Page 46: ...0051 0234 0089A 2 5M 8488057 1 Code Set E VM0306B VM0303B 2 5M BBZ0399 1 Operation Manual CU HD1300F S3 O M 1 Connector HDBB 25P 8AAE000854 1 Plug Case HDB CTH 4 40 10 JYHS003 1 Connector HDEB 9S 05 2PBB018260 1 Plug Case HDE CTH 4 40 10 JYH0051 1 Connector HDEB 9P 05 8AAE000718 1 Plug Case HDE CTH 4 40 10 JYH0051 1 Written guarantee U Written guarantee MGA0915 1 ...

Reviews: