27
PLC1/AVC5-UB
(Continued from previous page)
Model
Item
Specification
Condition etc.
Detection of AVC
Connection Condition
Ensure the following:
(1) If AVC and LCD is disconnected, or
(2) AC supply for AVC is off,
LCD Front LED will be: Orange (Blinking)
LCD Power state will be: Stand-By Mode
LCD Individual
Burn-in Function
It must operate by the LCD independent.
It must give a change indication of whole surface
monochrome.
The operation starts by pressing
Sub power SW for 5 seconds.
Turn off the Sub SW to cancel.
Measuring
Accumulated
ON time
To answer the accumulated time of ON mode
by the request of AVC.
If the address of EEPROM doesn’t have the
designated
data
below,
ensure
automatic
initialization is executed, and the data is written.
EEPROM Address
Designated Data
EEPROM
Automatic
Initialization
Key Operation
Sub Power SW: To be able to change-over
ON/Stand-By mode.
SII169 Configuration
DATA Setting
When the power is ON, store the data at the
SII169 Configuration EEPROM
(I002 BR24L08FJ) for data storage.
(1) When the power is turned ON for the first
time, conduct the writing.
(2) From the next time, check the data every
time the power is turned ON, and if it isn’t the
designated data, overwrite the correct one.
‘
’
Summary of Contents for 32HDL51M
Page 23: ...23 PLC1 AVC5 UB Specification Features 2 of 2 ...
Page 53: ...53 PLC1 AVC5 UB ...
Page 54: ...54 PLC1 AVC5 UB ...
Page 55: ...55 PLC1 AVC5 UB ...
Page 57: ...57 PCL1 AVC5 UB EXPLODED VIEW MONITOR TABLE OF CONTENTS MODEL 32HDL51 ...
Page 62: ...62 PLC1 AVC5 UB This page left blank intentionally ...
Page 63: ...PRINTED CIRCUIT BOARDS 63 PCL1 AVC5 UB ...
Page 80: ...80 PLC1 AVC5 UB ...