HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1)
213
10.41
Set Multiple (C6h)
Command Block Output Registers
Command Block Input Registers
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-
Feature
-
-
-
-
-
-
-
-
Error
…See Below…
Sector Count
V
V
V
V
V
V
V
V
Sector Count
-
-
-
-
-
-
-
-
Sector Number
-
-
-
-
-
-
-
-
Sector Number
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Device/Head
1
-
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-
Command
1
1
0
0
0
1
1
0
Status
…See Below…
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N AMN
BSY RDY
DF
DSC DRQ
COR
IDX
ERR
0
0
0
0
0
V
0
0
0
V
0
-
-
0
-
V
Table 159
Set Multiple Command (C6h)
The Set Multiple command enables the device to perform Read and Write Multiple commands and establishes
the block size for these commands. The block size is the number of sectors to be transferred for each interrupt.
If an invalid block size is specified, an Abort error will be returned to the host, and Read Multiple and Write
Multiple commands will be disabled.
Output Parameters To The Device
Sector Count.
The block size to be used for Read Multiple and Write Multiple commands. Valid block
sizes can be selected from 0, 1, 2, 4, 8 or 16. If 0 is specified, then Read Multiple and
Write Multiple commands are disabled.
Summary of Contents for 3.5-INCH Deskstar HDP725050GLAT80
Page 11: ...HITACHI Deskstar CinemaStar P7K500 Hard Disk Drive specification Rev 1 1 1 ...
Page 118: ...HITACHI Deskstar CinemaStar P7K500 Hard Disk Drive specification Rev 1 1 110 ...
Page 122: ...HITACHI Deskstar CinemaStar P7K500 Hard Disk Drive specification Rev 1 1 114 ...
Page 273: ...HITACHI Deskstar CinemaStar P7K500 Hard Disk Drive specification Rev 1 1 265 ...
Page 278: ...HITACHI Deskstar CinemaStar P7K500 Hard Disk Drive specification Rev 1 1 270 ...