– 8 –
CP-X960WA
CP-X970W
Indicator display
The POWER indicator, LAMP indicator and TEMP indicator will light or blink in the following cases.
Lamp is not inserted or
lamp door is not closed.
Securely insert the lamp or
close the lamp door.
Accumulated lamp operation
time has exceeded 2,000
hours
Replace lamp and reset the
accumulated lamp operation
time.
POWER indicator LAMP indicator TEMP indicator
Meaning
Remedy
Lights orange
Lights red
Lights red
Lights red
Lights red
Lights green
Blinks green
Blinks orange
Standby mode
During warming up
During operation
During cooling down
Lamp cannot light
Cool projector by power off for
60 minutes.
If the indicator is still lit, lamp
may be defective. Replace.
Blinks red
Blinks red
Blinks red
Blinks red
Cooling fan accidented
Replace fan.
Goes off
Goes off
Goes off
Goes off
Goes off
Goes off
Goes off
Goes off
Goes off
Goes off
Goes off
Goes off
When inside temperature becomes high, to protect the projector, the lamp may be turned off and the lamp
indicator lights red, or the projector will be shut down and the all indicator display goes off.