80
Troubleshooting
Regarding the indicator lamps (continued)
POWER
indicator
LAMP
indicator
TEMP
indicator
Description
Blinking
In
Red
or
Lighting
In.
Red
Turned
off
Lighting
In.
Red
There is a possibility that the interior portion
has become heated.
Please.turn.the.power.off,.and.allow.the.projector.to.cool.down.at.least.
20.minutes ..After.the.projector.has.sufficiently.cooled.down,.please.make.
confirmation.of.the.following.items,.and.then.turn.the.power.on.again .
•.Is.there.blockage.of.the.air.passage.aperture?
•.Is.the.air.filter.dirty?
•.Does.the.peripheral.temperature.exceed.40°C?
•.Is.the.projector.used.at.an.altitude.of.about.1600.m.or.
higher?.If.the.projector.is.used.at.an.altitude.of.about.
1600.m.or.higher,.set.ALTITUDE.of.the.SERVICE.item.
in.the.OPTION.menu.to.HIGH.
(
60
)
.
Lighting
In.
Green
Simultaneous
blinking in
Red
It is time to clean the air filter.
Please.immediately.turn.the.power.off,.and.clean.or.
change.the.air.filter.referring.to.the.section.“Cleaning.
and.replacing.the.air.filter” ..After.cleaning.or.changing.
the.air.filter,.please.be.sure.to.reset.the.filter.time ..
After.the.remedy,.reset.the.power.to.ON .
Lighting
In.
Green
Alternative
blinking in
Red
There is a possibility that the interior portion
has become overcooled.
Please.use.the.unit.within.the.usage.temperature.
parameters.(0°C.to.40°C) ...
After.the.treatment,.reset.the.power.to.ON .
•.When.the.interior.portion.has.become.overheated,.for.safety.purposes,.
the.projector.is.automatically.shut.down,.and.the.indicator.lamps.may.also.be.
turned.off ..In.such.a.case,.disconnect.the.power.cord,.and.wait.at.least.45.minutes ..
After.the.projector.has.sufficiently.cooled.down,.please.make.confirmation.of.the.
attachment.state.of.the.lamp.and.lamp.cover,.and.then.turn.the.power.on.again .
NOTE