background image

Customer  Service

 

Door lock

 

5  

4  

3

 

Part  Number

 

WW10

371567

 

Nominal  Voltage

 

230V+10%/-15%

 

Time for  locking

 

Max.6" at 20  °C

 

Time for  unlocking

 

Max.120" at 20  °C

 

Drain pump

 

Part  Number

 

WW1057577

6

 

Flow

 

14L/min +/-2L/min  at  1.25m

 

Input  Power

 

30W

 

Nominal  Voltage

 

220-240V

 

Resistance

 

160 ohms

 

Summary of Contents for WFN9012

Page 1: ...ustomer Service Manual WFN9012 WFN9012S Content 1 Safety 2 Specification 3 Control Panel 4 Structure Perspective 5 Fault Codes and Test Procedure 6 Parts Specification 7 Wiring Diagram Series number G75201300201 ...

Page 2: ...damage or injury This appliance must be connected to a sound electrical earth path It is important to avoid electrical shock and for electrical safety that this appliance must be earthed Do not use extension leads or multi socket adaptors Attention 1 Disconnect the appliance from the electrical power supply before commencing any clearing or maintenance 2 Any safety features installed by the manufa...

Page 3: ...umspin speed 1200rpm The maximumwash volume 9 0kg Temperature range 95 Colour White Dimensions cms H 850 x W 595 x D 620 Netweight 74KG Voltage 220 240V Frequency 50Hz Fuse 13A Heater Power 1900W Powercord 170 cms Drum volume 64 Litres Door diameter 450 mm Dooropenangle 135 ...

Page 4: ......

Page 5: ...Perspective 4 1 4 2Inlet system ispe to tu b Main wash fill valve Prewash fill valve as Dispe nser Door frame assembly Dispenser to tub hose Main wash fill valve Prewash fill valve Detergent dispenser assembly Dispenser to tub hose ...

Page 6: ...Customer Service 4 3Tub 4 4 Drainsystem 4 5 Door assembly Pump to tub hose Drain hose Dr ain pump ...

Page 7: ...Customer Service 5 Fault Codes and Test Procedure ...

Page 8: ...own to 45 rpm and rotate both clockwise and anti clockwise in an effort to redistribute the load It will try again at 93 rpm If the load is now balanced the program will continue to spin as normal The program will attempt to distribute the load 10 times before displaying Unb at the end of the cycle if it was not possible to balance the load ...

Page 9: ...und the selector All the icons will be displayed for 1sec then C1 will be displayed If the above operation cannot befinished in 60 sec error code F25 will be displayed C1 Water fill test Fill for 8 sec into the Prewash compartment Fill 8 sec into the Main wash compartment Fill for 8 sec into the Softener compartment using both fill valves If the water level does not reach the preset level the main...

Page 10: ... 1200rpm UM Motor 220v Askoll 46l Part Number WW10542580 Belt ratio i 13 3 I 1 Nominal Voltage 220V Resistance at 20 C Stator full field 1 7750 ohms 7 Stator tapped filed 0 8670ohms 7 Rotor 1 9 0 ohms 7 Speed table triac 1030 ohms 7 High 52 Protect type Hot ...

Page 11: ...rt Number WW10371567 Nominal Voltage 230V 10 15 Time for locking Max 6 at 20 C Time for unlocking Max 120 at 20 C Drain pump Part Number WW10575776 Flow 14L min 2L min at 1 25m Input Power 30W Nominal Voltage 220 240V Resistance 160 ohms ...

Page 12: ...e valve I I I Pressureswitch Part Number WW10612793 Water Level 55 25mm 5mm Overflow 300mm 20mm Part Number WW10282207 Nominal Voltage 230V AC 6 I 15 50Hz Nominal Power 6W Resistance 3820 Ohm 10 Flow 8 L min 5 from 1 5 to 5 ...

Page 13: ... Inductances 2x1 Mh 30 50 Nominal Discharging resistance 470K0 5 0 5W Heater Part Number WW10448715 Nominal Power 1900W Heat conductor resistance R20 25 50 5 Temperature 0 30 40 50 60 70 95 Resistance 35 975k 9 786k 6 653k 4 608k 3 243k 2 332k 1 093k Resistance tolerance 5 8 3 7 3 1 2 6 2 0 2 5 3 7 ...