TIP!
To avoid incompatibility issues, use only certified video adapters available from
Hope Industrial Systems. Many 3rd-party signal adapters are known to cause
signaling issues�
Power Connection
The HIS-ML19 is available with either AC or DC power input.
AC power input models accept 100 to 240 VAC, 1.5/0.75 A, 60/50 Hz. Loosen the retaining clip
for the power cable on the rear of the monitor� Connect the AC power cable to the power input
port on the monitor then retighten the retaining clip. Connect the other end into a nearby outlet.
HAZ
LOC
NOTE: If the retaining clip screw is not tightened, the product will not
comply with Class I, II, III, Division 2 Hazardous Location requirements.
DC power input models accept 9�6 to 36�6 VDC, 2�5 to 0�65 A, Class 2 or SELV/LPS�
1�
With main power disconnected, hook up incoming
power wires to the DC input terminal blocks
according to the label markings. Securely tighten
terminal block screws�
2�
Plug the connector into the unit and secure by
tightening the two side screws.
HAZ
LOC
NOTE: If steps 1 and 2 are not performed,
the product will not comply with Class I, II, III,
Division 2 Hazardous Location requirements.