OCTOPUS 8M/16M/24M/OS32
Release 10 05/2012
25
Grounding the device
The device is grounded via the separate ground screw.
Use toothed washers to ensure good electrical conductivity at the
connection.
Note:
The shielding ground of the connectable twisted pair lines is
connected to the housing as a conductor.
2.1.5
Connecting the supply voltage,
starting up
Mount the connector for the supply voltage and the signal contact on the
front of the device.
When you connect the supply voltage, you start up the device.
2.1.6
Connecting the data lines
You can connect terminal devices and other segments at the ports of the
device via twisted pair cables.
10/100 Mbit/s twisted pair connection
(4-pin M12 connector)
10/100 Mbit/s ports enable the connection of terminal devices or
independent network segments according to the IEEE 802.3 100BASE-
TX / 10BASE-T standard.
These ports support:
Autonegotiation
Autopolarity
Autocrossing (if autonegotiation is activated)
100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode
10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
Delivery state: autonegotiation activated
The socket housing is electrically connected to the housing.
Install the data lines according to your requirements.
Use a shielded CAT5 cable or better.
Use a shielded 4-pin M12 plug.
Figure
Pin
Function
1
TD+ Transmit Data +
2
RD+ Receive Data +
3
TD
−
Transmit Data
−
4
RD
−
Receive Data
−
Housing: shield
Table 4:
Pin assignment of a TP/TX interface (M12 socket)