background image

The naming of copyrighted trademarks in this manual, even when not specially indicated, should 
not be taken to mean that these names may be considered as free in the sense of the trademark 
and tradename protection law and hence that they may be freely used by anyone.

© 2012 Hirschmann Automation and Control GmbH

Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, 
translation, conversion into any electronic medium or machine scannable form is not permitted, 
either in whole or in part. An exception is the preparation of a backup copy of the software for 
your own use. For devices with embedded software, the end-user license agreement on the 
enclosed CD applies.

The performance features described here are binding only if they have been expressly agreed 
when the contract was made. This document was produced by Hirschmann Automation and 
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right 
to change the contents of this document without prior notice. Hirschmann can give no guarantee 
in respect of the correctness or accuracy of the information in this document.

Hirschmann can accept no responsibility for damages, resulting from the use of the network 
components or the associated operating software. In addition, we refer to the conditions of use 
specified in the license contract.

You can get the latest version of this manual on the Internet at the Hirschmann product site 
(www.hirschmann.com).

Printed in Germany
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Tel.: +49 (0)1805 14-1538

OCTOPUS 8M/16M/24M/OS32          039 679-002-10-0512

-8.5.12

Summary of Contents for OCTOPUS 16M-8PoE-2FX

Page 1: ...11 12 13 14 15 16 17 18 P1 P2 RM FAULT V 24 ACA Power 1 2 P Managed ETHERNET Switch x y OCTOPUS OS32 Produktcode IP ADDRESS Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 1 2 3 4 5 48V DC 48V DC Function...

Page 2: ...cribed here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s k...

Page 3: ...er Ethernet 14 2 Assembly and start up 17 2 1 Installing the device 17 2 1 1 Unpacking and checking 17 2 1 2 Installing the SFP modules optional 17 2 1 3 Connecting the connector for supply voltage an...

Page 4: ...4 OCTOPUS 8M 16M 24M OS32 Release 10 05 2012...

Page 5: ...sonal injury if the instructions are not followed This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid...

Page 6: ...ed pro perly and correctly Furthermore it must be operated and serviced carefully Warning Do not use the device in safety related applications in particular where life and limb may be in danger Supply...

Page 7: ...es certified for hazardous locations Power input and output I O wiring must be in accordance with Class I Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 and in accor...

Page 8: ...iar with the setup assembly startup and operation of this product and are appropriately qualified for their job This includes for example those persons who have been trained or directed or authorized...

Page 9: ...rsonnel trained for this purpose Relevant for OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M 2FX OCTOPUS OS32 08xx02O6O6 Note LED or LASER components in compliance with IEC 60825 1 2007 CLASS 1 LASE...

Page 10: ...s Note The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values FCC note This device complies with part 15 of the FCC rules Opera...

Page 11: ...ncy of the switching operations Check the resistance of the closed relay contacts and the switching function depending on the frequency of the switching operations Hirschmann is continually working to...

Page 12: ...undancy Configuration user manual Graphical User Interface reference manual Command Line Interface user manual The Industrial HiVision Network Management Software provides you with additional options...

Page 13: ...ice variant you can choose various media to connect terminal devices and other infrastructure components twisted pair cable multimode F O singlemode F O There are convenient options for managing the d...

Page 14: ...2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX The OCTOPUS Train devices meet the requirements of EN 50155 Railway applications electronic systems in railway vehicles 1 2 2 Devices with Power over...

Page 15: ...e individual ports are not electrically insulated from each other The following conditions are met in accordance with IEEE 802 3af Endpoint PSE Alternative A Device Number of FX ports Number of TX por...

Page 16: ...on Pin 1 2 3 4 5 0V FAULT 3 4 2 1 TP Ports 3 4 5 6 7 8 9 10 3 4 5 6 7 8 9 10 TP Ports 3 4 2 1 P1 P2 RM FAULT V 24 ACA Power 1 2 3 4 5 Function Pin 1 2 3 4 TX RX N C GND Produktcode IP ADDRESS 3 4 1 2...

Page 17: ...1 Installing the device 2 1 1 Unpacking and checking Check that the contents of the package are complete see page 39 Scope of delivery Check the individual parts for transport damage 2 1 2 Installing...

Page 18: ...rtightness of the OCTOPUS 8M 16M 24M OS32 device only use voltage supply cables with a diameter within the specified range Connecting the supply voltage Redundant power supplies can be used Both input...

Page 19: ...DC for 1 min Output power 150 W Current limitation 5 A Power supply unit and PoE media module form a limited power source according to IEC 60950 1 The external PoE power supply unit must be able to p...

Page 20: ...ivated The loss of ring redundancy reserve A detected error during the self test Incorrect configuration of the HIPER Ring or ring coupling The following condition is also reported in RM mode Ring red...

Page 21: ...in a location where the climatic threshold values specified in the technical data are adhered to Make sure the environment does not heat the device It can be mounted on temperature isolating material...

Page 22: ...22 OCTOPUS 8M 16M 24M OS32 Release 10 05 2012 Figure 3 Dimensions of the following devices OCTOPUS 8M shown in fig OCTOPUS 8M Train OCTOPUS 8M 6PoE OCTOPUS 8M 8PoE...

Page 23: ...012 23 Figure 4 Dimensions of the following devices OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 2FX shown in fig OCTOPUS 16M 8PoE OCTOPUS 16M 8PoE 2FX OCTOPUS OS32 080802T6T6TPEPHH OCTOPUS OS32 080802O6...

Page 24: ...16M 24M OS32 Release 10 05 2012 Figure 5 Dimensions of the following devices OCTOPUS 24M OCTOPUS 24M 8PoE OCTOPUS 24M Train OCTOPUS 24M 2FX shown in fig OCTOPUS OS32 081602T6T6TPEPHH OCTOPUS OS32 081...

Page 25: ...twisted pair cables 10 100 Mbit s twisted pair connection 4 pin M12 connector 10 100 Mbit s ports enable the connection of terminal devices or independent network segments according to the IEEE 802 3...

Page 26: ...duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode Power over Ethernet PoE Delivery state autonegotiation activated The socket housing is electrically connected to the housing The PoE...

Page 27: ...is electrically connected to the housing Install the data lines according to your requirements Use a shielded CAT5 cable or better Use a shielded 8 pin M12 plug Connect the cable shield to the connec...

Page 28: ...g port 1 TX 1 RX 2 RX 2 TX 3 TX 3 RX 4 RX 4 TX M12 4 pin on RJ45 crossed MDI to MDI terminal device 1 TX 3 RX 2 RX 1 TX 3 TX 6 RX 4 RX 2 TX M12 4 pin on RJ45 1 1 MDI to MDI X Switch 1 TX 1 RX 2 RX 3 T...

Page 29: ...the use of SFP modules see page 17 Installing the SFP modules optional OCTOPUS OS32 08xx02O6O6TPEPH1 The SFP slots are occupied with Fast Ethernet transceivers M Fast SFP SM LC EEC 2 2 Display elemen...

Page 30: ...nfiguration via DHCP LED Display Color Activity Meaning P1 Supply voltage 1 Green Lights up The supply voltage is on None The supply voltage is too low P2 Supply voltage 2 Green Lights up The supply v...

Page 31: ...cal 100 Mbit s ports 100 Mbit s full duplex All other ports autonegotiation Ring manager disabled ACA interface ACA21 M12 The ACA socket has an interface for the local connection of an AutoConfigurati...

Page 32: ...certain Hirschmann devices AutoConfiguration Adapter ACA11 M12 is not designed to be used with OCTOPUS 8M 16M 24M OS32 devices Always use the ACA21 M12 if you want to use an AutoConfiguration Adapter...

Page 33: ...e fig 8 Figure 8 SFP mounting tool 1 mounting side 2 barbed hooks 3 disassembly side Insert the SFP mounting tool into the SFP module so that the barbed hooks point to the base plate of the device and...

Page 34: ...Train OCTOPUS 24M 8PoE 2 540 g OCTOPUS 24M 2FX 2 570 g OCTOPUS OS32 0816 2 700 g Operating voltage OCTOPUS without PoE Safety extra low voltage SELV PELV redundant inputs disconnected Relevant for Nor...

Page 35: ...ltage max 60 V DC or max 30 V AC SELV Climatic conditions during operation Surrounding air temperature 40 F 158 F 40 C 70 C Humidity 10 100 condensing Air pressure minimum 795 hPa 2000 m maximum 1060...

Page 36: ...s 150 kHz 80 MHz 10 V EN 61000 4 9 Impulse shaped magnetic fields only OCTOPUS Train 300 A m EMC emitted interference EN 55022 Class A Yes FCC 47 CFR Part 15 Class A Yes German Lloyd Classification Co...

Page 37: ...0 29 dB 47 104 km 0 25 dB km 19 ps nm km LH LC SM 1550 nm 9 125 m 10 29 dB 55 140 km 0 18 dB kmb b with ultra low loss optical fiber 18 ps nm km Table 12 Fiber port 100BASE FX SFP fiber optic Fast Eth...

Page 38: ...n PD powered device 8 Class0 PD 17 0 W 150 0 W 58 Btu IT h 79 Btu IT h OCTOPUS 24M 13 5 W 46 Btu IT h OCTOPUS24M Train 13 5 W 46 Btu IT h OCTOPUS 24M 2FX 14 9 W 51 Btu IT h OCTOPUS 24M 8PoE non PD pow...

Page 39: ...request Device Scope of delivery OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8PoE OCTOPUS 8M 6PoE OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 8PoE OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M OCTOPUS 24M...

Page 40: ...able for use within an IP67 area Device Order number OCTOPUS 8M 943 931 001 OCTOPUS 8M Train 943 983 001 OCTOPUS 8M 8PoE 943 967 001 OCTOPUS 8M 6PoE 943 967 101 OCTOPUS 16M 943 912 001 OCTOPUS 16M Tra...

Page 41: ...8 pin X coded Length 1 m Length 2 m Length 5 m 942 081 001 942 081 002 942 081 003 Transition M12 D coded to RJ45 934 498 001 Locking screw set 25 pcs 942 057 001 SFP mounting tool for IP67 socket 942...

Page 42: ...s in railway vehicles EN 55022 IT equipment radio interference characteristics EN 61000 6 2 Generic norm immunity in industrial environments EN 61131 2 Programmable logic controllers FCC 47 CFR Part 1...

Page 43: ...E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation throu...