Installation MACH1000
Release 06 03/2021
41
Figure 13: Power supply unit characteristic value G
(see on page 54 “General
:
AC voltage (pictured above) or DC voltage (pictured below)
Connecting
1 - Supply voltage
2 - Signal contact
Note:
Use copper wire with cross-section AWG16 ... AWG12 (0.75 mm
2
...
3.0 mm
2
) and stripping length 12 mm.
For
every
supply voltage to be connected, perform the following steps:
Verify the required conditions for connecting the voltage supply.
See “Supply voltage” on page 7.
To insert the cable, you open the terminal lock by positioning the
screwdriver as illustrated below and pressing on the lever.
Connect the protective conductor with the clamp.
Connection
Characteristic
value C
Characteristic
value G- VDC
Characteristic
value G -VAC
, pin 1
Protective conductor
Protective conductor
Protective conductor
-/N, pin 2
Minus terminal of the
supply voltage
Minus terminal of the
supply voltage
Neutral conductor
+/L, pin 3
Plus terminal of the
supply voltage
Plus terminal of the
supply voltage
Line conductor
Table 7:
Pin assignment of spring-loaded terminal for voltage supply
4 5
Relay
4 5
G
4 5
Relay
4 5
3
2
1
3
2
1
-/N +/L
3
2
1
3
2
1
-/N +/L
2
1
-
+
2
1