56
Installation MACH1000
Release 06 03/2021
Climatic conditions
during operation
Minimum clearance around
the device
Top and bottom sides of device: 2 in (5 cm)
Left and right device side: 3.94 in (10 cm)
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
Standard
+32 °F ... +140 °F
(0 °C ... +60 °C)
Extended
bcdef
b. If you use SFP modules without the extension “EEC”, then an operating temperature range
of +32 °F ... +140 °F (0 °C ... +60 °C)
(see on page 65 “Accessories”.)
c. For devices equipped with more than 14 FO ports, the maximum operating temperature
decreases gradually.When equipped with 28 FO ports, the maximum operating temperature
is +158 °F (+70 °C).
d. MACH1000 device equipped with Fast Ethernet modules characteristic value GG
(Singlemode Long Haul FX DSC 124.27 mi (200 km)): +32 °F ... +140 °F (0 °C ... +60 °C).
e. -40 °F ... +185 °F (-40 °C ... +85 °C ) for devices with PoE, for devices with FL ports and for
devices with 4 × Gigabit Ethernet ports.
f.
Relevant for hazardous areas and approvals ISA 12.12.01 Class I Division 2, UL 508: The
maximum operating temperature (ambient air) is +158 °F (+70 °C) for the device variants
characteristic value U and F and +140 °F (+60 °C) for the device variant characteristic value
S
(see on page 9 “Use in Hazardous Locations”.)
-40 °F ... +185 °F
(-40 °C ... +85 °C)
Humidity
5 % ... 95 % (non-condensing)
Air pressure
up to 6562 ft (2000 m; 795 hPa), higher
altitudes upon request
Climatic conditions
during storage
Ambient air temperature
a
Standard
-40 °F ... +185 °F
(-40 °C ... +85 °C)
Extended
-40 °F ... +185 °F
(-40 °C ... +85 °C)
Humidity
5 % ... 95 % (non-condensing)
Air pressure
up to 6562 ft (2000 m; 795 hPa), higher
altitudes upon request
Pollution degree
2
Protection classes Laser protection
Class 1 according to EN 60825-1
Degree of protection
IP30