![Hirschmann HiSecOS EAGLE20 User Manual Download Page 48](http://html1.mh-extra.com/html/hirschmann/hisecos-eagle20/hisecos-eagle20_user-manual_2137998048.webp)
48
Installation EAGLE20/30
Release 12 03/2021
Climatic
conditions
during
operation
Ambient air temperature
a
Devices with operating temperature
characteristic value S (Standard):
+32 °F ... +140 °F (0 °C ... +60 °C)
Devices with operating temperature
characteristic value E and T (extended):
-40 °F ... +158 °F (-40 °C ... +70 °C)
b,c
Humidity
5 % ... 95 %
(non-condensing)
Air pressure
min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (-1312 ft; -400 m)
Climatic
conditions
during storage
Ambient air temperature
d
-40 °F ... +185 °F (-40 °C ... +85 °C)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (-1312 ft; -400 m)
Signal contact
“FAULT”
Switching current
max. 1 A SELV according to IEC 60950-1 or
ES1 according to IEC/EN 62368-1
Switching voltage
max. 60 V DC or max. 30 V AC SELV
according to IEC 60950-1 or ES1 according to
IEC/EN 62368-1
Pollution degree
2
Protection
classes
Laser protection
Class 1 in compliance with IEC 60825-1
Degree of protection
IP20
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
b. Only use SFP transceivers with the “EEC” extension.
c. +185 °F (+85 °C) for 16 hours (tested according to IEC 60068-2-2)
d. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
Summary of Contents for HiSecOS EAGLE20