Appearance after crimping 
 
The appearance after crimping is shown in Picture2. The dielectric of the cable may be deformed 
but it doesn’t affect the product’s function.       
 
 

 

 
 

 

GT21B-2426/1.6-2.9PCF Appearance after crimping 

 
 

 

 
 

 

GT21B-2426/1.6-2.9SCF Appearance after crimping 

 

Picture2 Appropriate appearance after crimping 

 
The shield braid may be trapped between the edges of the shield barrel but it does not affect the 
quality of the product unless it exceeds the area of the shield barrel. 
 

 

Jan.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Summary of Contents for GT21B

Page 1: ...1B Terminal Instruction Manual APPROVED KI HIROKAWA 20210701 CHECKED MH YAMAGUCHI 20210701 DESIGNED HK WATANABE 20210701 WRITTEN HK WATANABE 20210701 TECHICAL SPECIFICATION ETAD T0685 01 0 1 8 FORM HC...

Page 2: ...onfiguration GT21B 2426 1 6 2 9SCF Female terminal GT21B 2426 1 6 2 9PCF Male terminal Shield barrel Insulation Barrel Insulation Barrel Shield barrel Wire barrel Carrier Wire barrel Carrier Jan 1 202...

Page 3: ...ow Cable cut dimensions GT21B 2426 1 6 2 9SCF S type housing GT21T 1S HU GT21 1S HU Cable cut dimensions GT21B 2426 1 6 2 9PCF P type housing GT21N 1PP HU Note The dimensions of the stripping specific...

Page 4: ...the terminal plate Picture1 In case of interference the terminal cannot be set up correctly Verify the crimping data of the appropriate cable and measure the C H as shown on the cross section below Wh...

Page 5: ...he product s function GT21B 2426 1 6 2 9PCF Appearance after crimping GT21B 2426 1 6 2 9SCF Appearance after crimping Picture2 Appropriate appearance after crimping The shield braid may be trapped bet...

Page 6: ...0 1 There is no problem in quality if the wire can be verified at the edge of the wire barrel 2 In case of inspecting by appearance verify that the cable dielectric exceeds b1 Bendinig up bending down...

Page 7: ...LTD ETAD T0685 01 0 7 8 FORM HC0011 9 2 Twisting 5 MAX 5 MAX Cutoff tab 0 3MAX Crimp burr height 1 0 05MAX 2 0 15MAX 3 0 05MAX Bell mouth P 0 1 0 4 Jan 1 2022 Copyright 2022 HIROSE ELECTRIC CO LTD Al...

Page 8: ...not to deform terminals when touching them Do not store terminals in a dusty place Do not apply intense shocks to terminals Do not put wire harnesses on the floor Connectors are easily affected by sh...

Reviews: