HIROSE ELECTRIC CO.,LTD.
ETAD-T0685-01
0
8
/
8
FORM HC0011-9-2
△
(4)
Recommended inspection
①
Appearance
Should be free from flaws, deformations, plating separation etc.
②
Withstand voltage
Should be free from short circuit or insulation breakage when 600V AC is applied for one
second.
2mA leak current should be regarded as insulation breakage.
③
Conduction
The inner conductor and outer conductor should be conductive.
4.
Instructions
(1)
Do not touch the terminal contacts or inside of the barrel.
(2)
Do not put any object on a terminal. Do not drop terminals. Otherwise, terminals may be
deformed or become dirty. Handle terminals carefully.
(3)
Do not pull terminals forcedly when they are entangled. Disentangle carefully to avoid
deforming them.
(4)
Be careful not to deform terminals when touching them.
(5)
Do not store terminals in a dusty place.
(6)
Do not apply intense shocks to terminals.
(7)
Do not put wire harnesses on the floor.
(8)
Connectors are easily affected by shocks. Do not throw or swing them.
(9)
Do not handle parts in such a manner as the connector is deformed or flawed or terminals
are deformed.
5.
Storage Conditions
Storage place Temperature & humidity conditions
Storage period
Indoor storage
15
~
30
℃、
60%RH or less
Six months (in our packing condition)
Store the products in a place that meets the following conditions, if they cannot be stored in
an air-conditioned warehouse as shown above. Do not store the products in a place with much
humidity or dust, exposure to direct sunlight, etc.
Storage place Temperature & humidity conditions
Storage period
Indoor storage
-30
~
60
℃、
60%RH or less
Six months (in our packing condition)