background image

1

2017.8

0.5mm Pitch, 2.8mm high, Single Action Lock at bottom contact point, FPC/FFC/Shield FFC connector

FH63 Series

Fig.3

Robust lock firmly retains FPC/FFC.

GND contact and FFC GND plate 
contact at multiple points.

Mated condition 

(correct position)

Insufficient insertion condition
 (incorrect position)

21.94mm

5.15mm

Single action lock (Dimension diagram : 30pos.)

Fig.1

Fig.2

FPC

FFC

Shield FFC

Shield FFC

GND contact

Two-point contact design for dust prevention

Fig.4

Fig.5

Supports FPC/FFC/Shield FFC

High FPC retention force

FPC/FFC can be checked from the top surface after mating.

OK

NG

Shielded FFC is acceptable for EMI prevention.

Insert FPC/FFC

 without opening 

the lock lever before insertion!

2.8mm

Features

1. Automatic single action locking design

· Single action locking by simply inserting FPC after mounting 

contributes to enhanced workability. (Fig.1)
(Lock release by operating the lock lever when removing.)

· Operation of the lock lever is not required at the time of 

mating FPC. Can be inserted with one hand.
Contributes to reduced assembly time.
The lock lever will not be damaged by operation.
Mating failure is reduced by eliminating the need to operate 
a lever while mating.

2.  Two-points of contact prevents contact failure by dust

· High contact reliability by independent spring two-point 

contact design, preventing contact failure by dust. (Fig.2)

3.  Supports FPC/FFC/Shield FFC

· FH63 allows you to choose from FPC/FFC/Shield FFC.
· Shielded FFC is acceptable for EMI prevention.

 

(Fig.3)

4. High FPC retention force

· The circuit is automatically locked after FPC/FFC is inserted 

by a single action. The notches on both sides of FPC are 
held by the lock lever, generating a high FPC retention 
force in spite of the small contact. (Fig.4)

5. Visual inspection on the mated status of FPC/FFC is possible.

· As the notches on both sides of FPC can be checked from 

the top surface after inserting FPC/FFC, insufficient 
insertion during assembly is prevented. (Fig.5)

6. Environmental

· Halogen free
*AS defined by IEC 61249-2-21. 

Br : 900ppm max, Cl : 900ppm max, Br+Cl : 1,500ppm 
max

Mar.1.2018  Copyright 2018 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Summary of Contents for FH63 Series

Page 1: ...ime of mating FPC Can be inserted with one hand Contributes to reduced assembly time The lock lever will not be damaged by operation Mating failure is reduced by eliminating the need to operate a leve...

Page 2: ...tance 100m max No damage cracks or parts dislocation Acceleration of 981m s2 duration of 6 ms sine half wave waveform 3 cycles in each of the 3 axes 7 Damp heat Steady state Contact resistance 100m ma...

Page 3: ...15 B 0 15 Signal contact No 1 Polarity mark Grounding contact No 1 Grounding contact No 2 Pickup area Cavity No Reinforcing metal tabs Lead of reinforcing metal tabs Signal contact Grounding contact S...

Page 4: ...19 5 19 1 5 24 9 11 FH63 50S 0 5SH Under planning Note 1 50 24 5 24 2 29 9 13 FH63 60S 0 5SH Under planning Note 1 60 29 5 29 1 5 34 9 16 Note 1 Contact positions without HRS No are currently under pl...

Page 5: ...ng film 0 33 0 03 Grounding plate Shield 1 1 0 3 M 1 1 0 3 0 5 0 3 nX 0 05 W W BRecommended Dimensions of FPC FFC Shield FFC Units mm Part No HRS No No of Contacts B J K L M FH63 10S 0 5SH Under plann...

Page 6: ...m adhesive Reinforcing film Grounding plate adhesive Grounding plate Surface treatment Shield tape Polyester Adhesive Annealed copper foil Adhesive Polyester Adhesive Polyester Adhesive Conductive tap...

Page 7: ...4400 0 30 44 40 4 20 2 49 4 45 4 FH63 40S 0 5SH 580 4403 0 40 44 40 4 20 2 49 4 45 4 FH63 50S 0 5SH Under planning Note 1 50 56 52 4 26 2 61 4 57 4 FH63 60S 0 5SH Under planning Note 1 60 56 52 4 26 2...

Page 8: ...eflow environment Room air Solder Paste type Sn 3 0Ag 0 5Cu M705 GRN360 K2 V made by Senju Metal Industry Co Test PCB PCB material and size Glass epoxy 45 25 1mm Land size per recommended on page 4 Me...

Page 9: ...with the lock lever closed The lock lever does not need to be operated before inserting FPC Caution Do not open the lock lever when FPC is not inserted Additionally the lock lever does not need to be...

Page 10: ...nd in a horizontal plane in reference to the guides on both ends of the connector mating port Insert in a manner that it won t be diagonal to the insertion direction Example 5 When inserting do not mo...

Page 11: ...nd leaves a large gap between FPC and the housing FPC is not inserted deep enough leaving a large gap between FPC and the housing The protrusion of the lock lever runs over the FPC tab The protrusion...

Page 12: ...en it over this angle Example 13 Do not pick and raise the lock lever off or pull it Example 14 Be sure to operate the lock lever by hand and do not operate it with sharp edged tools such as tweezers...

Page 13: ...plied to the lock lever in the opposite direction Lock lever Lock lever Lock lever Load is concentrated on the rotation axis and leads to breakage Rotation axis Sharp edged tools Lock lever Lock lever...

Page 14: ...C the lever does not need to be operated after removal Example 20 Caution Do not pull out FPC while the lever is locked Example 21 This connector is equipped with the FPC retention mechanism by means...

Page 15: ...tact failure or damage disconnection of FPC Therefore please take some measure to fix FPC etc Example 24 Example 25 Don t place any parts under the FPC that will interfere with FPC Example 26 As for t...

Page 16: ...Please control the board warpage as much as possible While the coplanarity of this connector is 0 1mm or less defective soldering could occur if the board warpage is considerable When mounted on FPC...

Reviews: