FH63 Series

0.5mm Pitch, 2.8mm high, Single Action Lock at bottom contact point, FPC/FFC/Shield FFC connector

B

Connector operation and points to note

[Operation method]

[Cautions for PCB layout]

Depending on the routing of FPC to mate, a load may be applied to the connector, which could lead to failure.
In order to prevent failure, please consider the following concerning the mechanism design.

[Caution]

· When routing the FPC, please be careful that FPC is not pulled and routing is carried out with a margin. 
· Please check that the reinforcing film is placed horizontal to the board surface. (Example 23)
· Please insure there is no load applied to the connector in the pulling, inserting or lateral direction. 
  A bent FPC, it could cause contact failure or damage/disconnection of FPC. Therefore, please take some 

measure to fix FPC etc. (Example 24)(Example 25)

· Don't place any parts under the FPC that will interfere with FPC. (Example 26)
· As for the flexibility of FPC, please make adjustments with the FPC manufacturer.
· Please ensure the FPC has adequate insertion space when designing the layout so that it is not inserted 

diagonally.

  Additionally, ensure the insertion space is not too short for FPC. Please adopt adequate parts layout and 

length for FPC.

· When you design the board/layout, please secure a space required for operations.

Lock lever

Lock lever

Reinforcing film

Reinforcing film

Reinforcing film

Lock lever

Lock lever

The state where a load
 is applied to FPC

The state where a load 
is applied to FPC

Mounting parts 
interfering with FPC

NG

NG

OK

NG

(Example 25)

(Example 26)

(Example 23)

(Example 24)

Mar.1.2018  Copyright 2018 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Summary of Contents for FH63 Series

Page 1: ...ime of mating FPC Can be inserted with one hand Contributes to reduced assembly time The lock lever will not be damaged by operation Mating failure is reduced by eliminating the need to operate a leve...

Page 2: ...tance 100m max No damage cracks or parts dislocation Acceleration of 981m s2 duration of 6 ms sine half wave waveform 3 cycles in each of the 3 axes 7 Damp heat Steady state Contact resistance 100m ma...

Page 3: ...15 B 0 15 Signal contact No 1 Polarity mark Grounding contact No 1 Grounding contact No 2 Pickup area Cavity No Reinforcing metal tabs Lead of reinforcing metal tabs Signal contact Grounding contact S...

Page 4: ...19 5 19 1 5 24 9 11 FH63 50S 0 5SH Under planning Note 1 50 24 5 24 2 29 9 13 FH63 60S 0 5SH Under planning Note 1 60 29 5 29 1 5 34 9 16 Note 1 Contact positions without HRS No are currently under pl...

Page 5: ...ng film 0 33 0 03 Grounding plate Shield 1 1 0 3 M 1 1 0 3 0 5 0 3 nX 0 05 W W BRecommended Dimensions of FPC FFC Shield FFC Units mm Part No HRS No No of Contacts B J K L M FH63 10S 0 5SH Under plann...

Page 6: ...m adhesive Reinforcing film Grounding plate adhesive Grounding plate Surface treatment Shield tape Polyester Adhesive Annealed copper foil Adhesive Polyester Adhesive Polyester Adhesive Conductive tap...

Page 7: ...4400 0 30 44 40 4 20 2 49 4 45 4 FH63 40S 0 5SH 580 4403 0 40 44 40 4 20 2 49 4 45 4 FH63 50S 0 5SH Under planning Note 1 50 56 52 4 26 2 61 4 57 4 FH63 60S 0 5SH Under planning Note 1 60 56 52 4 26 2...

Page 8: ...eflow environment Room air Solder Paste type Sn 3 0Ag 0 5Cu M705 GRN360 K2 V made by Senju Metal Industry Co Test PCB PCB material and size Glass epoxy 45 25 1mm Land size per recommended on page 4 Me...

Page 9: ...with the lock lever closed The lock lever does not need to be operated before inserting FPC Caution Do not open the lock lever when FPC is not inserted Additionally the lock lever does not need to be...

Page 10: ...nd in a horizontal plane in reference to the guides on both ends of the connector mating port Insert in a manner that it won t be diagonal to the insertion direction Example 5 When inserting do not mo...

Page 11: ...nd leaves a large gap between FPC and the housing FPC is not inserted deep enough leaving a large gap between FPC and the housing The protrusion of the lock lever runs over the FPC tab The protrusion...

Page 12: ...en it over this angle Example 13 Do not pick and raise the lock lever off or pull it Example 14 Be sure to operate the lock lever by hand and do not operate it with sharp edged tools such as tweezers...

Page 13: ...plied to the lock lever in the opposite direction Lock lever Lock lever Lock lever Load is concentrated on the rotation axis and leads to breakage Rotation axis Sharp edged tools Lock lever Lock lever...

Page 14: ...C the lever does not need to be operated after removal Example 20 Caution Do not pull out FPC while the lever is locked Example 21 This connector is equipped with the FPC retention mechanism by means...

Page 15: ...tact failure or damage disconnection of FPC Therefore please take some measure to fix FPC etc Example 24 Example 25 Don t place any parts under the FPC that will interfere with FPC Example 26 As for t...

Page 16: ...Please control the board warpage as much as possible While the coplanarity of this connector is 0 1mm or less defective soldering could occur if the board warpage is considerable When mounted on FPC...

Reviews: