background image

1

GP3000H Soft-type Cable for 

GP2000H Conversion Adapter 

<RS-232C/RS-422 >

(with connector)

 Installation Guide

Thank you for purchasing Pro-face’s 

GP3000H Soft-type Cable for GP2000H 

Conversion Adapter <RS-232C/RS-422> 

(with connector) (Hereafter referred to as 

“this cable”). This cable is an optional cable 

designed to connect the GP3000H series unit 

(Hereafter referred to as the “GP3000H”) and 

the GP2000H series RS-232C or RS-422 

Conversion Adapter (Hereafter referred to as 

the “GP2000H Conversion Adapter”).
This cable comes in two types of 

communication methods, RS-232C or 

RS-422, each of which is available in two 

lengths of 3m and 10m. 
(This installation guide is valid for the 

common mode filter RSAL-2001W 

manufactured by TDK-Lambda 

Corporation.)

Safety Precautions

• Be sure to confirm that power is not 

being supplied to the GP3000H and 

the external devices before connecting 

this cable. Failure to do so can result in 

an electric shock.

• Do not modify this cable, since it may 

result in a fire or electric shock.

• This cable is not appropriate for use 

with aircraft control devices, aerospace 

equipment, central trunk data 

transmission (communication) devices, 

nuclear power control devices, or 

medical life support equipment, due to 

these devices inherent requirements of 

extremely high levels of safety and 

reliability.

• When using this cable with 

transportation vehicles (trains, cars 

and ships), disaster and crime 

prevention devices, various types of 

safety equipment, non-life support 

related medical devices, etc. use 

redundant and/or failsafe system 

designs to ensure reliability and safety.

Package Contents

(1) This Cable (1)
(2) Common Mode Filter (1)

- RSAL-2001W manufactured by TDK-

Lambda Corporation

(3) FG wire (1)
(4) Connector Cap (1)

 (attached to the cable connector)

(5) Installation Guide (1) (This Guide)

This cable has been carefully packed, with 

special attention to quality. However, should 

you find anything damaged or missing, please 

contact your local distributor immediately.

About the Manual

About the GP3000H 

• GP3000H Series Hardware Manual
• Maintenance/Troubleshooting
• GP-Pro EX Reference Manual “Hand 

Held GP”

How to connect the GP3000H to 

peripheral equipment 

• This Guide
• GP-Pro EX Device/PLC Connection 

Manual “GP3000H Series Connection 

Guide”

About the GP2000H Conversion 

Adapter 

• GP2000H Series RS-232C Conversion 

Adapter (GP2000H-AP232) Installation 

Guide 

• GP2000H Series RS-422 Conversion 

Adapter (GP2000H-AP422) Installation 

Guide 

The manuals can be selected from the help 

menu of GP-Pro EX or downloaded from 

Pro-face Home Page.

URL
http://www.pro-face.com/otasuke/

REV.A

Summary of Contents for GP3000H

Page 1: ...es or medical life support equipment due to these devices inherent requirements of extremely high levels of safety and reliability When using this cable with transportation vehicles trains cars and ships disaster and crime prevention devices various types of safety equipment non life support related medical devices etc use redundant and or failsafe system designs to ensure reliability and safety P...

Page 2: ...C Conversion Adapter GP2000H AP232 GP2000H RS 422 Conversion Adapter GP2000H AP422 Mitsubishi PLC A QnA FX Series 2 Port Adapter II GP070 MD11 DC24V RS 232C Cable GP410 IS00 O 1 This cable GP3000H CBLSD232 3M GP3000H CBLSD232 10M GP3000H DC24V RS 232C Cable Prepared by user Host Controller PLC etc Host Controller PLC etc RS 422 Cable Prepared by user This cable GP3000H CBLSD422 3M GP3000H CBLSD422...

Page 3: ...ning torque of 0 5N m Avoid bending this cable excessively and pulling this cable with excessive force Excessive bending and pulling can result in cable disconnection Name Model Description GP3000H Soft type 3 m Cable for GP2000H Conversion Adapter RS 232C with connector GP3000H CBLSD232 3M The cable between the GP2000H Series RS 232C Conversion Adapter and the GP3000H equipped with D Sub connecto...

Page 4: ...3 Turn the cable connector lock ring to lock the connector so that the small mark for LOCK on the lock ring is aligned with the small mark on the cable connector Removal 1 Unlock the connector that has been locked in the mounting procedure Turn the lock ring as shown so that the small mark is displaced from the mark Then pull out the cable by holding the cable connector To disconnect the cable be ...

Page 5: ... RESERVE Not labeled 5 OP C OP 6 OP GND OPG 7 BUZZ OUT BZ 8 DOUT GND DOG 9 EMG0A EM0A Emergency switch 0A Normally Open 2 2 To improve noise resistance be sure to twist each pair of wires close to the terminal block 10 EMG0B EM0B Emergency switch 0B Normally Open 2 11 EMG1A EM1A Emergency switch 1A Normally Closed 2 12 EMG1B EM1B Emergency switch 1B Normally Closed 2 13 EMG2A EM2A Emergency switch...

Page 6: ... s power supply cord should not be bundled with or kept close to main circuit lines high voltage high current or input output signal lines To improve noise resistance make the power cord as short as possible If the supplied voltage exceeds the GP3000H s range connect a voltage transformer Between the line and the ground be sure to use a low noise power supply If there is an excess amount of noise ...

Page 7: ...nding wire should have a diameter greater than 2 mm2 Create the connection point as close to the GP3000H as possible and make the wire as short as possible When using a long grounding wire replace the thin wire with a thicker wire and place it in a duct Input Output Signal Line Cautions All GP3000H Input and Output signal lines must be separated from all operating circuit power cables If the opera...

Page 8: ...oofing standards Pro face s GP3000H Conversion Adapter model AGP3000H ADPCOM 01 and a dedicated cable sold separately are necessary to overcome these restrictions Please refer to Accessories in Chapter 1 Overview in the GP3000H Series Hardware Manual UL c UL Approval The system constructing the following three components does not conform to UL c UL standards GP3000H This cable GP2000H RS 232C RS 4...

Reviews: