2. Connecting the GP3000H 

Attachment

(1) Before connection, remove the cable's 

connector cap and GP3000H connector 
cover. To remove the cable's connector 
cap, pull out the cable by holding the 
cable connector as shown.

• To disconnect the cable from the connector 

cap, be sure to hold the cable connector 
and pull it out. If you hold other parts of 
the cable (lock ring, etc.), the cable cannot 
be disconnected.

(2) Insert the cable connector to the 

GP3000H cable connector until it clicks. 
Match the 

 points and insert the cable 

connector, as shown below.

• Be sure to insert the cable connector as 

shown.  Failure to do so might result in 
damage to the connector.

(3) Turn the cable connector lock ring to 

lock the connector, so that the small 

 

mark (for LOCK) on the lock ring is 
aligned with the small 

 mark on the 

cable connector.

Removal

(1) Unlock the connector that has been 

locked in the mounting procedure. (Turn 
the lock ring as shown so that the small 

 mark is displaced from the 

 mark). 

Then, pull out the cable by holding the 
cable connector.

• To disconnect the cable, be sure to hold the 

cable’s connector and pull it out. If you 

hold other parts of the cable (lock ring, 

etc.), the cable cannot be disconnected.

Pull out this cable by holding 

the cable connector.

connector cap

GP3000H 

cable connector 

Match the 

 points and insert 

the cable connector until it clicks.

Lock Ring

Align the small 

 and 

 

marks to lock 

the connector.

2. Pull out the cable by holding 

the cable connector.

1. Turn the lock ring to 

unlock the connector.

Summary of Contents for GP3000H

Page 1: ...es or medical life support equipment due to these devices inherent requirements of extremely high levels of safety and reliability When using this cable with transportation vehicles trains cars and ships disaster and crime prevention devices various types of safety equipment non life support related medical devices etc use redundant and or failsafe system designs to ensure reliability and safety P...

Page 2: ...C Conversion Adapter GP2000H AP232 GP2000H RS 422 Conversion Adapter GP2000H AP422 Mitsubishi PLC A QnA FX Series 2 Port Adapter II GP070 MD11 DC24V RS 232C Cable GP410 IS00 O 1 This cable GP3000H CBLSD232 3M GP3000H CBLSD232 10M GP3000H DC24V RS 232C Cable Prepared by user Host Controller PLC etc Host Controller PLC etc RS 422 Cable Prepared by user This cable GP3000H CBLSD422 3M GP3000H CBLSD422...

Page 3: ...ning torque of 0 5N m Avoid bending this cable excessively and pulling this cable with excessive force Excessive bending and pulling can result in cable disconnection Name Model Description GP3000H Soft type 3 m Cable for GP2000H Conversion Adapter RS 232C with connector GP3000H CBLSD232 3M The cable between the GP2000H Series RS 232C Conversion Adapter and the GP3000H equipped with D Sub connecto...

Page 4: ...3 Turn the cable connector lock ring to lock the connector so that the small mark for LOCK on the lock ring is aligned with the small mark on the cable connector Removal 1 Unlock the connector that has been locked in the mounting procedure Turn the lock ring as shown so that the small mark is displaced from the mark Then pull out the cable by holding the cable connector To disconnect the cable be ...

Page 5: ... RESERVE Not labeled 5 OP C OP 6 OP GND OPG 7 BUZZ OUT BZ 8 DOUT GND DOG 9 EMG0A EM0A Emergency switch 0A Normally Open 2 2 To improve noise resistance be sure to twist each pair of wires close to the terminal block 10 EMG0B EM0B Emergency switch 0B Normally Open 2 11 EMG1A EM1A Emergency switch 1A Normally Closed 2 12 EMG1B EM1B Emergency switch 1B Normally Closed 2 13 EMG2A EM2A Emergency switch...

Page 6: ... s power supply cord should not be bundled with or kept close to main circuit lines high voltage high current or input output signal lines To improve noise resistance make the power cord as short as possible If the supplied voltage exceeds the GP3000H s range connect a voltage transformer Between the line and the ground be sure to use a low noise power supply If there is an excess amount of noise ...

Page 7: ...nding wire should have a diameter greater than 2 mm2 Create the connection point as close to the GP3000H as possible and make the wire as short as possible When using a long grounding wire replace the thin wire with a thicker wire and place it in a duct Input Output Signal Line Cautions All GP3000H Input and Output signal lines must be separated from all operating circuit power cables If the opera...

Page 8: ...oofing standards Pro face s GP3000H Conversion Adapter model AGP3000H ADPCOM 01 and a dedicated cable sold separately are necessary to overcome these restrictions Please refer to Accessories in Chapter 1 Overview in the GP3000H Series Hardware Manual UL c UL Approval The system constructing the following three components does not conform to UL c UL standards GP3000H This cable GP2000H RS 232C RS 4...

Reviews: