9
common GND terminal (open collector output DC 30 V / 0.1A).
+DC 24 V
: Power source for powering external equipment. The power
capacity is DC 24 V / 0.3A.
Mode Switches
1
: The work complete notification buzzer (built in) no longer sounds if switched
OFF.
2
: The panel display turns off if switched OFF.
3
: The reverse rotation count up operation turns off if switched OFF.
4
: When switched OFF, the unit will only work once the set input signal is received.
5
: Unused.