MEMORY HiCORDER MR8880

CAT III 600 V 

insulation performance

• Operating temperature range: 

-10°C to 50°C

• Built to withstand mechanical shocks and vibrations 
  (ships standard with side protectors)

Simply select what you’d like to measure and follow the on-
screen instructions to select the appropriate settings. The re-
corder can be easily configured to measure voltage drops and 
power outages.

• Maximum 600V AC/DC input - no need for a differential probe
• 4 completely isolated channels let you simultaneously record  
  data on a 3-phase power line plus have one extra channel

Make settings easily with 

PRESETS

Tough against harsh environments

Capture high- to low-voltage signals in a single device

Rugged, Professional and Ready for the Field

Summary of Contents for HiCORDER MR8880

Page 1: ...ions to select the appropriate settings The re corder can be easily configured to measure voltage drops and power outages Maximum 600V AC DC input no need for a differential probe 4 completely isolate...

Page 2: ...22 F Even when operating on battery power the MR8880 can take measurements from 0 C 32 F to 40 C 104 F n Rugged damage resistant design features standard side protectors that guard the instrument s ca...

Page 3: ...the channel you wish to use Select the power line voltage Select the frequency Select the threshold Select the high speed or real time function The auto range settings can be enabled when using the hi...

Page 4: ...kS s 500 s 8m 20 s 100ms DIV 1 kS s 1 ms 16m 40 s The maximum recording length is fixed regardless of the number of channels in use Measure RMS value fluctuations for a power line over an extended pe...

Page 5: ...aking measurements in an outdoor setting The dis play is even engineered for easy viewing in the presence of reflections a What if there s no power available in the vehicle being tested A high capacit...

Page 6: ...hannels isolated input and outputs logic has common GND Maximum sampling rate 1Msamples s 1 s cycle all channels simultaneously Memory capacity 14bit 1 M words ch 1 word 2 bytes not expandible Externa...

Page 7: ...open and 8 k or lower short Response speed 500ns or lower Max allowable input 0 to 50V DC the maximum voltage that can be applied across input pins without damage LOGIC PROBE MR9321 01 Function Detec...

Page 8: ...06 ft roll type 10 rolls set Other options CARRYING CASE C1003 Includes compartment for options soft case type CONNECTION CORD L9217 Cord has insulated BNC connectors at both ends for signal output 1...