Hioki HiCORDER MR8880 Manual Download Page 8

HEADQUARTERS

  81 Koizumi, Ueda, Nagano, 386-1192, Japan
  TEL +81-268-28-0562   FAX +81-268-28-0568 
  http://www.hioki.com / E-mail: [email protected]

HIOKI USA CORPORATION

  TEL +1-609-409-9109   FAX +1-609-409-9108
  http://www.hiokiusa.com / E-mail: [email protected]

All information correct as of Aug. 7, 2017.  All specifications are subject to change without notice.

MR8880E15-78B      Printed in Japan

DISTRIBUTED BY

HIOKI (Shanghai) SALES & TRADING CO., LTD.

  TEL +86-21-63910090   FAX +86-21-63910360
  http://www.hioki.cn / E-mail: [email protected]

HIOKI SINGAPORE PTE. LTD.

  TEL +65-6634-7677   FAX +65-6634-7477
  E-mail: [email protected]

HIOKI KOREA CO., LTD.

  TEL +82-2-2183-8847   FAX +82-2-2183-3360
  E-mail: [email protected]

Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.

Leak Current 

*For commercial power lines, 50/60 Hz

CLAMP ON LEAK HiTESTER  3283

  10 mA range/10 μA resolution to 200 A range, 

with monitor/analog output 1 V f.s.

OUTPUT CORD  L9095

  Connect to BNC terminal, 1.5 m (4.92 ft) length

AC ADAPTER  9445-02

  For USA, 100 to 240 V AC, 9 V/ 1 A

AC ADAPTER  9445-03

  For EU 100 to 240 V AC, 9 V/ 1 A

Non

-co

nta

ct V

olta

ge m

eas

urin

g

NON-CONTACT AC VOLTAGE 

PROBE SP3000-01

 5 Vrms rated, 10 Hz to 100 kHz 

band width

NON-CONTACT 

AC VOLTAGE 

PROBE SP3000

 Sold individually

AC VOLTAGE 

PROBE 
SP9001

 Sold individually

500 A to 5000 A 

*For commercial power lines, 50/60 Hz

CLAMP ON PROBE  9018-50

  Good  phase  characteristics,  Frequency 

characteristics: 40 Hz to 3 kHz, 10 to 500 A 

AC range, output 0.2 V AC f.s.

CLAMP ON PROBE  9132-50

  Frequency characteristics: 40 Hz to 1 kHz, 

20 to 1000 A AC range, output 0.2 V AC f.s.

AC FLEXIBLE CURRENT SENSOR  

CT9667-01/-02/-03

  10 Hz to 20 kHz, 5000 A/ 500 A AC, 500 

mV/f.s. output, φ 100 to 254 mm (3.94 to 

10.00 in), 3 loop diameters

*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x.
*The separately available Conversion Cable CT9900 is required in order to use a sensor with PL23 (10-pin) terminal.

POWER SUPPLY for Current Sensors

SENSOR UNIT CT9555

 1ch, with Waveform output

CONNECTION CORD L9217

 

Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length

PL23 (10-pin) - ME15W (12-pin) conversion

CONVERSION CABLE CT9900

  Convert  PL23 (10-pin) terminal to ME15W (12-pin) terminal

Up to 1000 A (High precision) 

*ME15W (12-pin) terminal type

High-precision pull-through type, monitor the waveforms of DC to distorted AC current

AC/DC CURRENT SENSOR  9709-05

, 100 kHz band width, 500A

Monitor the waveforms of DC to distorted AC current

AC/DC CURRENT PROBE  CT6844-05

, 200 kHz band width, 500A

AC/DC CURRENT PROBE  CT6845-05

, 100 kHz band width, 500A

AC/DC CURRENT PROBE  CT6846-05

, 20 kHz band width, 1000A

St

or

ag

e m
ed

ia

*PC Card Precaution

Use only PC Cards sold by HIOKI. Compatibility and performance 

are not  guaranteed for PC cards made by other manufacturers. You 

may be unable to read from or save data to such cards.

PC CARD 2G 9830

  2 GB capacity

PC CARD 1G 9729

  1 GB capacity

PC CARD 512M 9728

  512 MB capacity

Includes a PC card adapter

Po

w

er s

up

ply

AC ADAPTER Z1002

 

For main unit, 100 to 240 V 

AC

BATTERY PACK Z1000

  NiMH, Charges while 

installed in the main unit

*Z1002 is a bundled accessory

PC S
oft

w

ar

e

WAVE PROCESSOR  9335

 

Convert data, print and display 

waveforms

Pr

in

te

r o

pti

on

s

PRINTER UNIT MR9000

  Printing width 100 mm (3.94 in), 

used together with the MR8880-
20 main body, includes 1 roll of 
recording paper

RECORDING PAPER 9234

  112 mm (4.41 in) × 18 m (59.06 ft), 

roll type, 10 rolls/set

Ot

he

r o

pti

on

s

CARRYING CASE 

C1003

 Includes compartment for 

options, soft case type

CONNECTION CORD 

L9217

 Cord has insulated BNC 

connectors at both ends, for 

signal output, 1.6 m (5.25 ft) 

length

Logic signal measurement

LOGIC PROBE  MR9321-01

  4 isolated channels, ON/OFF 

detection of AC/DC voltage 
(miniature terminal type)

LOGIC PROBE  9320-01

  4-channel type, for voltage/contact signal 

ON/OFF detection (response pulse width 
500 ns or more, miniature terminal type)

CONVERSION CABLE  9323

*Used for connecting the 

9320/9321/MR9321 and the 9324 
to the Memory HiCorder with 
small logic terminal models

* Only the small terminal types can be used.  * The 9323 is not required for 

the small-terminal types 9327, 9320-01, 9321-01 and MR9321-01.

In

pu

t c

ab

le (

E)

 

DIFFERENTIAL PROBE 9322

  For up to 1kV AC or 2kV DC, 

frequency band width up to 10MHz

 

AC ADAPTER 9418-15

  100 to 240 V AC.

*Voltage to ground is within this product's specifications. 

Separate power source is also required.

Cus

tom c

able

*For P9000. Inquire with your Hioki distributor.

(1) 

Bus powered USB cable

(2) 

USB(A)- Micro B cable

(3) 

3-prong cable

In

pu

t c

ab

le (

D)

DIFFERENTIAL PROBE 

P9000-01

 

Waveform only, up to 1 kV AC/

DC, band width up to 100kHz

DIFFERENTIAL PROBE 

P9000-02

  Waveform/RMS value switch-

able, up to 1 kV AC/DC, band 
width up to 100kHz

AC ADAPTER 

Z1008

  100 to 240 V AC

*Voltage to ground is within this product's specifications. 

Separate power source is also required.

In

pu

t c

ab

le (

B)

*Voltage is limited to the specifications of the iput section

CONNECTION CORD  L9198

  φ 5.0 mm (0.20 in) dia., cable allowing 

for up to 300 V input. 1.7 m (5.58 ft) 
length, small alligator clip

CONNECTION CORD  L9197

  φ 5.0 mm (0.20 in) dia., cable allowing 

for up to 600 V input. 1.8 m (5.91 ft) 
length, a detachable large alligator 
clips are bundled

GRABBER CLIP  9243

  Attaches to the tip of the banana 

plug cable, CAT III 1000 V, 196 
mm (7.72  in) length

CONNECTION CORD  L9790

  Flexible φ 4.1 mm (0.16 in) thin 

dia., cable allowing for up to 600 
V input. 1.8 m (5.91 ft) length

* The end clip is sold separately.

ALLIGATOR CLIP  L9790-01

  Red/black set attaches to the ends 

of the cables L9790

GRABBER CLIP  9790-02

 

Red/black set attaches to the ends 
of the cables L9790

* When this clip is attached to the end of the 

L9790, input is limited to CAT II 300 V. 
Red/black set.

CONTACT PIN  9790-03

 

Red/black set attaches to the ends 
of the cables L9790

L9790-01

9790-02

9790-03

L9790

In

pu

t c

ab

le (

A)

*Voltage is limited to the specifications of the iput section

Recommended

MR9000

Model : MEMORY HiCORDER MR8880

Model No. (Order Code) (Note)

MR8880-20

(4ch, printer unit option)

*Test leads are not included. Purchase the leads appropriate for 

your application separately

MR8880  Options in Detail

The CT7290 (available separately) is required in order to use these current sensors.

100 A to 2000 A (Medium speed)

AC/DC CURRENT SENSOR CT7631, 

(Auto zero  CT7731)

 DC, 1 Hz to 10 kHz (-3dB), 100 A, 1 mV/A output

AC/DC CURRENT SENSOR CT7636, 

(Auto zero  CT7736)

 DC, 1 Hz to 10 kHz (-3dB), 600 A, 1 mV/A output

AC/DC CURRENT SENSOR CT7642, 

(Auto zero  CT7742)

 DC, 1 Hz to 10 kHz (5 kHz), 2000 A, 1 mV/A output

DISPLAY UNIT CM7290

 Provides measurement, display, and output 

functionality when used with the CT7000s.

DISPLAY UNIT CM7291

 with built-in Bluetooth® wireless technology

Precautions when connecting a high-precision current sensor to a Memory HiCorder

Connecting to the MR8880/MR8875/MR8870

• High-precision current sensor (ME15W) + BNC cable 

 MR8880

• High-precision current sensor (PL23) +   BNC cable 

 MR8880

Other current sensor types

The MR8880 can be used with various types of current sensors and 
probes. For details, see product information on Hioki’s website.

Summary of Contents for HiCORDER MR8880

Page 1: ...ions to select the appropriate settings The re corder can be easily configured to measure voltage drops and power outages Maximum 600V AC DC input no need for a differential probe 4 completely isolate...

Page 2: ...22 F Even when operating on battery power the MR8880 can take measurements from 0 C 32 F to 40 C 104 F n Rugged damage resistant design features standard side protectors that guard the instrument s ca...

Page 3: ...the channel you wish to use Select the power line voltage Select the frequency Select the threshold Select the high speed or real time function The auto range settings can be enabled when using the hi...

Page 4: ...kS s 500 s 8m 20 s 100ms DIV 1 kS s 1 ms 16m 40 s The maximum recording length is fixed regardless of the number of channels in use Measure RMS value fluctuations for a power line over an extended pe...

Page 5: ...aking measurements in an outdoor setting The dis play is even engineered for easy viewing in the presence of reflections a What if there s no power available in the vehicle being tested A high capacit...

Page 6: ...hannels isolated input and outputs logic has common GND Maximum sampling rate 1Msamples s 1 s cycle all channels simultaneously Memory capacity 14bit 1 M words ch 1 word 2 bytes not expandible Externa...

Page 7: ...open and 8 k or lower short Response speed 500ns or lower Max allowable input 0 to 50V DC the maximum voltage that can be applied across input pins without damage LOGIC PROBE MR9321 01 Function Detec...

Page 8: ...06 ft roll type 10 rolls set Other options CARRYING CASE C1003 Includes compartment for options soft case type CONNECTION CORD L9217 Cord has insulated BNC connectors at both ends for signal output 1...

Reviews: