background image

i

―――――――――――――――――――――――――――

Introduction

――――――――――――――――――――――――

Introduction

Shipping Check

Thank you for purchasing this

HIOKI

"9636 RS-

232C CABLE." To get the maximum performance
from the product, please read this manual first, and
keep this at hand.

Request

We have tried to bring this manual as close to
perfection as we could achieve. If perchance you
find any unclear portions, mistakes, omissions, or
the like, we would be most obliged if you could
please notify us of them via any

HIOKI

agent, or

directly.

When the product is delivered, check and make sure
that it has not been damaged in transit.

If the product is damaged, or fails to operate
according to the specifications, contact your dealer
or

HIOKI

representative.

Check the 9636 product and the Supplied
Accessories

Main product

9636 RS-232C CABLE
(Straight, cord length 1.3 m, D-sub 9 pin, female)

Supplied accessories

Instruction manual 1

Summary of Contents for 9636

Page 1: ...9636 RS 232C CABLE INSTRUCTION MANUAL ...

Page 2: ......

Page 3: ...1 RS 232C CABLE Overview 1 1 1 Overview 1 1 2 Printing Contents 1 Chapter 2 Connection Procedure 4 2 1 Printer Model 4 2 2 Connection Procedure 5 Chapter 3 3286 20 Settings 6 3 1 OPTION Mode 6 3 2 DATA OUTPUT SETUP Mode 7 3 3 Default Settings 9 3 4 Print 10 Chapter 4 Troubleshooting 11 ...

Page 4: ......

Page 5: ... portions mistakes omissions or the like we would be most obliged if you could please notify us of them via any HIOKI agent or directly When the product is delivered check and make sure that it has not been damaged in transit If the product is damaged or fails to operate according to the specifications contact your dealer or HIOKI representative Check the 9636 product and the Supplied Accessories ...

Page 6: ...efore using the equipment The manufacturer disclaims all responsibility for any accident or injury except that resulting due to defect in its product Safety This Instruction Manual provides information and warnings essential for operating this product in a safe manner and for maintaining it in safe operating condition Before using this product be sure to carefully read the following safety notes ...

Page 7: ...d to locations on the product where the operator should consult corresponding topics in this manual which are also marked with the symbol before using relevant functions of the product In the manual this mark indicates explanations which it is particularly important that the user read before using the product The following symbols are used in this Instruction Manual to indicate the relative import...

Page 8: ...ng any of the interface connectors To avoid damaging cables do not kink or pull on the leads This product is designed for indoor use and operates reliably from 0 to 40 32 to 104 Attentions During Use In order to ensure safe operation and to obtain maximum performance from the product observe the cautions listed below ...

Page 9: ...e information Phase detection Progress time Function Voltage Range Current Range Voltage information Current information Power information Chapter 1 RS 232C CABLE Overview 1 1 Overview 1 2 Printing Contents Measurement data can be output by connecting a printer with the RS 232C cable supplied with the 9636 To print from the 3286 20 press the HOLD key for about one second to output the data ...

Page 10: ...le 2 Current harmonics Output format ALL Function Range Harmonic percentage Harmonics effective value Harmonic order 3 Printing Example 3 Output format DISP Outputs the data displayed on the 3286 20 LCD 1 1φP 2 REC 3 BATT Lo The battery low is expressed ...

Page 11: ... 1P_PF 1φPF Meter 3P_PF 3φPF Meter HARM_I Current harmonics HARM_U Voltage harmonics Phase information 0 5deg means Lead phase No sign means Lag phase NOTE As for the setting of the output format please refer to 3 2 DATA OUTPUT SETUP Mode BATT Lo is printed when the battery is completely discharged ...

Page 12: ...carefully to ensure proper operation Please use Model 1196 Recording Paper thermal paper 10 rolls or equivalent We strongly recommend that the above model be used because the other RS 232C printers would not work due to the control sequence difference Chapter 2 Connection Procedure 2 1 Printer Model Use our Model 9442 Printer and 1196 Recording Paper both optional Printer Model 9442 Seiko Instrume...

Page 13: ...e Printer Connection NOTE 2 2 Connection Procedure 1 Turn the 3286 20 and the printer off 2 Connect the 9636 RS 232C cable to the DATA OUTPUT terminal of the 3286 20 Be careful of the cable direction when connecting it to the 3286 20 ...

Page 14: ...TION mode 1 OPTION Types 2 To activate the OPTION mode hold the U key while pressing POWER to turn the 3286 20 on 3 The digit selected for changing the OPTION mode blinks Pressing the MODE key moves the blinking selection to the right and pressing the MAX MIN key moves it the left 4 Set the numerical value to by pressing the U and I keys to change the blinking digit 5 After setting all digits appr...

Page 15: ...e RS 232C communications speed item 2 04 RS 232C data length item 2 05 RS 232C stop bits item 2 06 and RS 232C parity bit item 2 07 must be set to be the same as printer settings 1 To activate the DATA OUTPUT SETUP mode hold the SET2 key while pressing the POWER key to turn the 3286 20 on 2 Select the appropriate settings Use the MODE and MAX MIN keys to increment and decrement the item number res...

Page 16: ... are saved Items 2 04 and later are not displayed unless item 2 03 is set to 6 Setting Details 1 DATA OUTPUT Function Item 2 01 off DATA OUTPUT Function disabled PRN Select the 9442 Printer for output 2 Output Format Item 2 02 FORM ALL Select all items for output DISP Select display items for output 3 RS 232C Communications Display Item 2 03 RS IF off No display DISP Display items 2 04 to 2 07 ...

Page 17: ... stop bits 7 RS 232C Parity Bit Item 2 07 PARI none Select no parity bit EVEN Select even parity bit ODD Select odd parity bit This procedure returns the RS 232C settings to their factory defaults 1 Hold the SET2 key while turning the power on 2 Press the HOLD key until is displayed 3 Press the HOLD key again to initialize the settings to their default values Default Values DATA OUTPUT Function OF...

Page 18: ...ey as turning power on will display and initialize all the saved settings RS 232C settings SETUP function and measurement status saving function Enable both the OPTION mode and the DATA OUTPUT SETUP mode then hold down the HOLD key for about one second to output the data ...

Page 19: ... and the 9442 match each other If the problem is not solved after the troubleshooting initialize the settings To initialize hold down the RANGE key as powering on The entire LCD will go on and will appear This will reset all the saved contents to their initial values Chapter 4 Troubleshooting Although the following problems might seem to be program malfunctions they can result from other causes So...

Page 20: ...12 Chapter 4 Troubleshooting ...

Page 21: ... 0562 E mail os com hioki co jp URL http www hioki co jp Printed in Japan 9636A980 03 All reasonable care has been taken in the production of this manual but if you find any points which are unclear or in error please contact your supplier or the Sales and Marketing International Department at HIOKI headquarters In the interests of product development the contents of this manual are subject to rev...

Page 22: ...Nagano 386 1192 Japan TEL 81 268 28 0562 FAX 81 268 28 0568 E mail os com hioki co jp HIOKI USA CORPORATION 6 Corporate Drive Cranbury NJ 08512 USA TEL 1 609 409 9109 FAX 1 609 409 9108 9636A980 03 02 08H Printed on recycled paper ...