background image

3M

 No Polish Connector  

8800-APC/AS/AGC SM SC/APC, 

AGC Angle Splice, 250/900 μm  

Using 3M

 Angle Fiber Cleaver  

2536-AGC

Instructions

April 2018

78-0015-4562-9-A

Summary of Contents for 2536-AGC

Page 1: ...3M No Polish Connector 8800 APC AS AGC SM SC APC AGC Angle Splice 250 900 μm Using 3M Angle Fiber Cleaver 2536 AGC Instructions April 2018 78 0015 4562 9 A ...

Page 2: ... physician Upon skin contact wash with soap and water Product Information Safety Data Sheet SDS or 3M Company St Paul MN 55144 1000 651 733 1110 Operator 55 Bare Fiber Handling c Caution Cleaved glass fibers are sharp and can pierce the skin Use tweezers when handling shards and dispose of them properly per your company health and safety instructions Fiber Cable Handling c Caution Optical fiber ca...

Page 3: ... free cloth and reagent grade isopropyl alcohol 1 2 Required tools which are available in the 3M Fiber Optic Angle Cleave Kit 8865 AGC a Fiber shard container b 3M Angle Fiber Cleaver 2536 AGC c 3M No Polish Connector Assembly Tool 8865 AT d 3M Fiber Snips e 3M Tri hole Stripping Tool 6365 KS b a c d e 3 78 0015 4562 9 A April 2018 ...

Page 4: ... using tight buffered or semi tight buffered fiber For 900 µm buffer fiber cut the buffer If the 900 µm slides easily from the fiber it is loose tube or semi tight buffered fiber 4 2 In this instance use the fiber holder s clamp to prohibit the buffer from moving or stretching during the stripping process Step 4 3 4 7 place the fiber into the fiber holder groove labeled semi tight with the fiber t...

Page 5: ...r and tight buffer 900 µm fiber the fiber should be placed in the fiber holder tool groove which is labeled TIGHT BUFFER For semi tight buffer fiber it should be placed in the groove labeled SEMI TIGHT BUFFER This provides the proper clamping force on the 900 µm buffer If the 250 µm fiber still moves inside the 900 µm buffer after it is clamped in the Semi Tight groove then the connector must be i...

Page 6: ...the funnel shaped fiber guide Edge to buffer aligning with the hole 4 11 Latch the clamp to secure the fiber in position 4 12 Insert the fiber holder in the cleaver laying the fiber between the two pins Slide the holder forward until it stops 4 13 Slide the funnel assembly back until it hits the stops on the fiber tool 4 14 Verify the fiber has no bow is between the guide pins and that the 900 μm ...

Page 7: ... end of the holder The amount of exposed fiber should be from 0 to 1 mm 0 04 in 1 mm 5 2 Place fiber holder in the assembly tool base 5 3 VERY SLOWLY slide the fiber holder towards the connector A bow in the fiber is started once the white line on the fiber holder is even with the white line BOW START on the base If a bow is not seen strip clean and cleave the fiber as shown in Section 4 and try i...

Page 8: ... verification is required or you need to test the link prior to placing in service you will per form this step now Do not proceed to step 6 2 until testing is complete If re termination is required please skip to Section 7 3M No Polish Connector NPC Re termination 6 2 Press release lever to allow forward motion of funnel Push ears to move funnel forward and actuate buffer clamp ear release lever 6...

Page 9: ...ox of NPCs and place it in the three slots provided on the underside of the NPC shell as shown 7 2 Firmly press the cap popper into the NPC shell until the activation cap is depressed Remove fiber and insert connector with the actuation cap facing up in the coupling pushing forward until it clicks Follow steps 2 2 through 6 1 to re terminate the NPC connector 7 3 Upon verification that connector h...

Page 10: ...anteed Before using this product you must evaluate it and determine if it is suitable for your intended application You assume all risks and liability associated with such use Any statements related to the product which are not contained in 3M s current publications or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon in writing by ...

Reviews: