7.4 Composite Waveforms (X-Y Waveforms)
187
7
Chap
ter 7 W
ave
form
Display Se
ttings
This applies to the Memory function only.
Any channels can be displayed as a composite during or after measurement. To
make a composite while measuring, measurement configuration settings and X-
Y composite have to be set before starting measurement. Refer to the appropri-
ate chapters for measurement configuration settings. This section describes the
composite waveform settings.
7.4
Composite Waveforms (X-Y Waveforms)
1
2
3
4
X-Y Waveforms
To open the screen: Press the
SET
key
Select
with the
SUB MENU
keys
Sheet Settings screen
See
Screen Layout (p. 174)
Composite setting is available both before and after measurement.
Operating Key
Procedure
1
Set the Display Type.
CURSOR
Move the cursor to the
[Display Type]
item.
F1 to F8
Select either choice.
2
Set Split-Screen display (p. 178).
CURSOR
Move the cursor to the
[Split-Screen]
item.
F1 to F8
Select the number of Graphs. (Available choices
depend on the Display Type setting.)
3
Set the Composite Area.
CURSOR
Move the cursor to the
[Area]
X-Y Composite
item.
F1 to F8
Select either choice.
4
Set line interpolation (as occasion demands).
CURSOR
Move the cursor to the
[Dot-Line]
item.
F1 to F8
Select either choice.
X-Y Comp
Displays X-Y waveforms.
Wave & X-Y
Displays both X-Y composite and
analog waveforms.
Whole
Use the whole range for the composite
waveform. (default setting) (default setting)
A-B
Use the range specified by the cursors.
Procedure to specify a range with A/B cur-
sors:(p. 200)
Dots
Do not interpolate straight lines. Input sig-
nals (sampling data) are displayed and re-
corded as is.
Line
Interpolate straight lines. This can improve
display visibility, although the display
speed is slower than Dots display.
(default setting)
"Making Partial Composites" (p. 189)
To make a partial composite while mea-
suring, first acquire waveforms and
specify the waveform range with A/B
cursors.
Summary of Contents for 8860-50
Page 2: ......
Page 12: ...Contents x...
Page 18: ...Reading this Manual 6...
Page 24: ...1 3 Interconnection and Block Diagrams 12...
Page 180: ...6 12 Making Trigger Settings on the Waveform Screen 168...
Page 246: ...8 15 Inserting and Searching for Event Marks on a Waveform 234...
Page 356: ...12 7 Print Examples 344 A B Waveform_________________________________________________...
Page 406: ...14 2 External I O 394...
Page 489: ......
Page 490: ......