7 Decommissioning 

DI 32 01 

Page 30 of 38 

HI 800 203 E Rev. 1.00 

7 Decommissioning 

Remove the supply voltage to decommission the module. Afterwards pull out the pluggable 
screw terminal connector blocks for inputs and outputs and the Ethernet cables. 

 

Summary of Contents for HIMatrix F60 DI 32 01

Page 1: ...HIMatrix Safety Related Controller DI 32 01 Manual HIMA Paul Hildebrandt GmbH Co KG Industrial Automation Rev 1 00 HI 800 203 E...

Page 2: ...HIMA directly HIMA appreciates any suggestion on which information should be included in the manual Equipment subject to change without notice HIMA also reserves the right to modify the written materi...

Page 3: ...d Inputs 11 3 1 1 1 Reaction in the Event of a Fault 11 3 1 1 2 Line Control 11 3 2 Equipment Scope of Delivery 13 3 3 Type Label 13 3 4 Assembly 14 3 4 1 Block Diagram 14 3 4 2 Front View 15 3 4 3 St...

Page 4: ...s and Error Codes for the Inputs 24 4 4 3 Digital inputs 25 5 Operation 27 5 1 Handling 27 5 2 Diagnosis 27 6 Maintenance 28 6 1 Faults 28 6 2 Maintenance Measures 29 6 2 1 Loading the Operating Syste...

Page 5: ...ing Transport Disposal This manual distinguishes between the following variants of the HIMatrix system Programming tool Processor operating system Communication operating system SILworX Version 7 and...

Page 6: ...rX ELOP II Factory Online Help Instructions on how to use ELOP II Factory Ethernet IP protocol INTERBUS protocol First Steps SILworX Introduction to SILworX using the HIMax system as an example HI 801...

Page 7: ...rly marked 1 3 1 Safety Notes The safety notes are represented as described below These notes must absolutely be observed to reduce the risk to a minimum The content is structured as follows Signal wo...

Page 8: ...Rev 1 00 1 3 2 Operating Tips Additional information is structured as presented in the following example i The text corresponding to the additional information is located here Useful tips and tricks a...

Page 9: ...of values Protection class Protection class III in accordance with IEC EN 61131 2 Ambient temperature 0 60 C Storage temperature 40 85 C Pollution Pollution degree II in accordance with IEC EN 61131...

Page 10: ...user program Faults in the wiring 2 3 Safety Precautions Observe all local safety requirements and use the protective equipment required on site 2 4 Emergency Information A HIMatrix system is a part...

Page 11: ...ed digital inputs These inputs are divided in 4 groups of 7 inputs and 1 group of 4 inputs I29 I32 Refer to Table 9 for more information on the terminal assignment Each group is equipped with a common...

Page 12: ...l 1 and reside in direct sequence one after the other If the following faults occur the FAULT LED located on the front plate of the controller blinks the inputs are set to low level and an evaluable e...

Page 13: ...Description Part no DI 32 01 Plug in module with 32 digital inputs SIL3 Cat 4 configurable with cross circuit monitoring 98 2200114 Table 4 Part Numbers 3 3 Type Label The type plate contains the foll...

Page 14: ...t Description DI 32 01 Page 14 of 38 HI 800 203 E Rev 1 00 3 4 Assembly This chapter describes the layout and function of the plug in module 3 4 1 Block Diagram Test 32 Channels I O Bus Figure 3 Block...

Page 15: ...DI 32 01 3 Product Description HI 800 203 E Rev 1 00 Page 15 of 38 3 4 2 Front View DI 32 01 Figure 4 Front View...

Page 16: ...ive de energized Table 6 I O LEDs 3 5 Product Data General Operating voltage 24 VDC 15 20 wss 15 provided by a power supply unit with safe isolation in accordance with IEC 61131 2 requirements Operati...

Page 17: ...e the module with the screws located on upper and lower extremity of the front plate The module is mounted Removing the Modules To remove a module from the rack 1 Remove the plugs from the module fron...

Page 18: ...nputs 15 21 20 I15 Digital input 15 21 I16 Digital input 16 22 I17 Digital input 17 23 I18 Digital input 18 24 I19 Digital input 19 25 I20 Digital input 20 26 I21 Digital input 21 27 EGND Ground Termi...

Page 19: ...ut wires 2 Activate noise blanking a signal must be present for at least two cycles before it is evaluated i Activating noise blanking increases the response time of the HIMatrix system i The measures...

Page 20: ...can also performed when the controller is under voltage 2 The enclosure in use must be able to safely dissipate the generated heat The power dissipation of the module DI 32 01 is 7 W at maximum depend...

Page 21: ...e of I O modules can be plugged in to slots 3 8 The module slots in SILworX and ELOP II Factory are numbered as follows Module Slot on the rack Slot in SILworX Slot in ELOP II Factory PS 01 1 CPU COM...

Page 22: ...can be read and set for the inputs including the corresponding error codes In the user program the error codes can be read using the variables assigned within the logic The error codes can also be di...

Page 23: ...short circuits or cross circuits DI Error Code WORD R Error codes for all digital inputs Coding Description 0x0001 Module fault 0x0002 FTT test of test pattern faulty 0x0004 FTT test 1st temperature t...

Page 24: ...the 1st DO channel 2 Pulse of the 2nd DO channel 8 Pulse of the 8th DO channel Table 12 SILworX System Parameters for Digital Inputs DI 32 01 Channels Tab 4 4 Configuring Using ELOP II Factory 4 4 1 C...

Page 25: ...Temperature threshold exceeded DI xx Error Code BYTE R Error codes for the digital input channels Coding Description 0x01 Fault in the analog input module 0x10 Short circuit of the channel 0x80 Inter...

Page 26: ...203 E Rev 1 00 System Signal R W Description DI Pulse Delay 10E 6 s UINT W Waiting time for line control detection of short circuits or cross circuits 1 LS LB short circuit open circuits Table 13 ELOP...

Page 27: ...IMatrix base plate and does not require any specific monitoring 5 1 Handling Handling of the controller during operation is not required 5 2 Diagnosis A first diagnosis results from evaluating the LED...

Page 28: ...acturer is authorized to repair the device module 6 1 Faults Refer to Chapter 3 1 1 1 for more information on the fault reaction of inputs NOTE If a failure occurs the module must be replaced to ensur...

Page 29: ...e system downtimes to load a current version of the operating system into the controller Refer to the release list to check the consequences of the new operation system version on the system Load the...

Page 30: ...01 Page 30 of 38 HI 800 203 E Rev 1 00 7 Decommissioning Remove the supply voltage to decommission the module Afterwards pull out the pluggable screw terminal connector blocks for inputs and outputs...

Page 31: ...chanical damage HIMatrix components must be transported in packaging Always store HIMatrix components in their original product packaging This packaging also provides protection against electrostatic...

Page 32: ...E Rev 1 00 9 Disposal Industrial customers are responsible for correctly disposing of decommissioned HIMatrix hardware Upon request a disposal agreement can be arranged with HIMA All materials must be...

Page 33: ...ronic System PFD Probability of Failure on Demand probability of failure on demand of a safety function PFH Probability of Failure per Hour probability of a dangerous failure per hour R Read The syste...

Page 34: ...dix DI 32 01 Page 34 of 38 HI 800 203 E Rev 1 00 Index of Figures Figure 1 Line Control 12 Figure 2 Sample Type Label 13 Figure 3 Block Diagram 14 Figure 4 Front View 15 Figure 5 Label for Ex Conditio...

Page 35: ...ers 13 Table 5 Status Indicators 16 Table 6 I O LEDs 16 Table 7 Product Data 16 Table 8 Specifications for Digital Inputs 16 Table 9 Terminal Assignment for the Inputs 18 Table 10 Module Slots 21 Tabl...

Page 36: ...Appendix DI 32 01 Page 36 of 38 HI 800 203 E Rev 1 00 Index diagnosis 27 fault reaction digital inputs 11 part number 13 specifications 16 surge 19...

Page 37: ......

Page 38: ...1014 HIMA Paul Hildebrandt GmbH Co KG P O Box 1261 68777 Br hl Germany Tel 49 6202 709 0 Fax 49 6202 709 107 E mail info hima com Internet www hima com HI 800 203 E by HIMA Paul Hildebrandt GmbH Co KG...