PCM412 - Manuale per l'utente
Programmation
26
27
3
Programmation
3.1
Automatic
3.2
Dip-Switch
limit stop
NOTE:
ALL TIMES THAT IS THE CENTRAL UNIT IS POWERED, IS ALWAYS
CARRIED CYCLE OF AN OPENING / CLOSING STORE FOR THE POSITION
OF END-RUN.
The central PCM412 not need to electromagnetic or electromechanical systems stop limit;
For the correct operation is necessary to store the travel of the gate
to identify and save the stop limit.WithThis operation, the central counting the number of revolutions of
the motors, allows the slowdown of the doors near the stop limit, and recognize the position of the gate
if an obstacle doesn't allow the normal cycle of opening and closing.
During the count you will have the lighting of LED ADJM1 for the geared motor 1 and the lighting of
LED ADJM2 for the geared motor 2.
Near the stop limit the doors will approaching at reduced speed.
The first start or any start after a gap of power, the
Central is running a complete cycle of open - close, and stores the number of revolutions of the
engines.
Completed installation, remove the two ratio-motor with release key, bringing the two doors in an
intermediate position and then proceed with the clamping.
Connect the batteries to the station and give an open command with a remote control or a mechanical
control type Sc1 or by pushing or P1 orP2 on the circuit.
Make sure when doing this there are no mechanical obstacles to the proper identification of the stop
limit.
Achieved closure of thr gate, the system has stored the number of revolutions of the engines
The system is equipped with an auto-correction for counting small change due to wear and thermal
expansion. The storage is not required until the central system is until the power still present.
If you proceed to the mechanical release the ratio motor or manual movement of the gate, remove
the power system and repeat the storage limit as above.
To start the installation must set the following Dip Switch:
1-2 Mode of operation
3
Closing wing time for the closing of two doors
4
Door hummering (for the unlocking of electric lock)
5
Flasher type used
6
NOT UTILIZED
7
Single or double door
8
Type of photocells used
NOTE: The setting of DIP SWITCH,must be done with central unit is OFF.
ON
Step-by-step with STOP
1
2
3
4
5
6
7
8
3.2.1
Mode of functionnement
The central unit PCM412 has 4 different operating modes selectablei with the Dip-Switch 1 and 2.
NOTE: A command of START1 during a cycle of partial opening never puts in motion the second door. A
command start2 during an opening cycle total effect on two doors. To move from a partial opening to a full
or vice versa you need to restart the gate from the closed position.
CLOSING
GATE
STATUS
CLOSE
OPENING
Opens and waits
following
command
And opens onl
door1
closed after
pause
FTC. Interna
FTC. Esterna
START 1
START 2
Prevents the opening Prevents the opening Prevents the opening
Without the gate, the
following command
closes it
Without the gate, the
following command
closes it.
Without the gate and
restoration expected
further control start
to continue opening.
Stop the gate to
disengagement takes
opening
Not effect
OPEN
Closes
Lock the gate
open. Restoration
expects a
following command
Lock the gate
open.Disengagement
waits for the
command start.
Lock the gate
open.To
hallway waiting
start command.
Stop the gate,the
following
command reopens.
Stop motion
and restoration
awaits further
command for
closing
Without the gate
and reopens to the
disengagement
Without the gate and
reopens
immediately
gate.
STOP
Step-by-step with automatic closing
ON
1
2
3
4
5
6
7
8
CLOSING
GATE
STATUS
CLOSE
OPENING
Opens and closes
after pause
And opens only door1
closed after
pause
FTC. Internal
FTC. External
START 1
START 2
Prevents the opening Prevents the opening Prevents the opening
Stop motion. A
following command
starts closing.
Stops.
A subsequent
command closes
both wings
Without the gate and
restoration expected
further control start
to continue opening.
Stop motion.
Disengagement
incorporates open
Not effect
PAUSE
Clear the break and
closes
immediately
Let the gate
open. Restoration
closed without
wait time
Prevents
reclosing. To
disengagement close
immediately place
Prevents
reclosing
Stop the closure.
A subsequent
command starts the
reopening
Stop the closure.
A subsequent
command starts the
reopening
Stop motion
and restoration
awaits further
command for
closing
Without the gate
and reopens to the
disengagement
Without the gate and
reopens
immediately
STOP
Closes
Stop the gate,the
following
command reopens.
Clear the break and
closes
immediately