18 English
ItemEquipment
ACD AGD,
AFD,
AND
DG-
CW
(SPX,
SP,
P)
DC-
TP,
DC-D
(SPX,
SP,
P)
AP-D 3CS,
4CS,
3SS,
4SS
AG-D
type 27
K
Support plate
—
—
—
—
X
—
—
L
Guard type 27
—
—
—
—
—
—
X
5
Technical data
If the product is powered by a generator or transformer, the generator or
transformer’s power output must be at least twice the rated input power
shown on the rating plate of the product. The operating voltage of the
transformer or generator must always be 5 % and -15 % of the rated
voltage of the product.
The information given applies for a rated voltage of 120 V. Actual figures can
vary for country-specific versions and if the voltage supply differs. For rated
voltage, frequency, input power and rated current, refer to the rating plate.
AG 500-11S
Rated current input
10.5 A
Rated frequency
60 Hz
Maximum disc diameter
5 in
Weight
5.5 lb
(2.5 kg)
Drive spindle thread
5/8"-11
6
Before use
CAUTION
Risk of injury.
The accessory tool may be hot or have sharp edges.
▶
Wear protective gloves when fitting, removing or adjusting the accessory
tool or other parts and when troubleshooting.
6.1 Fitting the side handle
▶
Screw the side handle into one of the threaded bushings provided.
6.2 Guard
▶
Observe the instructions for fitting the applicable guard.
Printed: 19.10.2018 | Doc-Nr: PUB / 5402264 / 000 / 01
Summary of Contents for AG 500-11S
Page 1: ...AG 500 11S English Printed 19 10 2018 Doc Nr PUB 5402264 000 01 ...
Page 2: ...Printed 19 10 2018 Doc Nr PUB 5402264 000 01 ...
Page 3: ...AG 500 11S Original operating instructions Printed 19 10 2018 Doc Nr PUB 5402264 000 01 ...
Page 4: ...Printed 19 10 2018 Doc Nr PUB 5402264 000 01 ...
Page 14: ...10 English Printed 19 10 2018 Doc Nr PUB 5402264 000 01 ...
Page 15: ...English 11 Printed 19 10 2018 Doc Nr PUB 5402264 000 01 ...
Page 32: ...28 English Printed 19 10 2018 Doc Nr PUB 5402264 000 01 ...
Page 33: ...Printed 19 10 2018 Doc Nr PUB 5402264 000 01 ...